Based on Finite Element Simulation: Optimization of Microneedle Structure and Mechanical Performance Analysis
Authors:
Open Access
- 1 November 2024
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2890 (1)
Abstract
Microneedles, as an innovative drug delivery technology, demonstrate great potential for application due to their superior performance in transdermal drug delivery. Compared with traditional injection needles, microneedles can reduce pain and the risk of infection after insertion into the skin, and have the potential to organically combine with other external technologies to further enhance the effectiveness of drug delivery and therapeutic effect. However, to achieve efficient drug delivery, the design and optimization of microneedles must comprehensively consider their mechanical properties and penetration depth. This study systematically analyzes the mechanical performance of microneedles by using finite element software to simulate the skin insertion process of single microneedles, dual microneedles, and microneedle arrays. Firstly, a simplified skin model and a two-dimensional axisymmetric model were established to simulate the penetration force and stress variations during the insertion of a single microneedle into the skin. Subsequently, the relationship between penetration force and depth for double and nine-needle arrays under different spacing conditions was studied. The simulation results show that the spacing between microneedles significantly affects their penetration performance: as the spacing increases, the penetration depth and force gradually decrease, but this effect diminishes when the spacing exceeds 500 μm. Ultimately, a centre spacing of 600 μm was determined to be the optimal spacing for the microneedle arrays. This study not only confirms the validity of the theoretical analysis but also provides an important basis for the design and optimization of microneedle structures.Keywords
This publication has 12 references indexed in Scilit:
- The Finite Element Analysis Research on Microneedle Design Strategy and Transdermal Drug Delivery SystemPharmaceutics, 2022
- Microneedle Arrays for Drug Delivery and Diagnostics: Toward an Optimized Design, Reliable Insertion, and PenetrationAdvanced Materials Interfaces, 2022
- Recent Advances in Microneedle-Based Sensors for Sampling, Diagnosis and Monitoring of Chronic DiseasesBiosensors, 2021
- Engineering Microneedle Patches for Improved Penetration: Analysis, Skin Models and Factors Affecting Needle InsertionNano-Micro Letters, 2021
- Microneedle Technology: An Insight into Recent Advancements and Future Trends in Drug and Vaccine DeliveryASSAY and Drug Development Technologies, 2021
- Acceptability of an inactivated influenza vaccine delivered by microneedle patch: Results from a phase I clinical trial of safety, reactogenicity, and immunogenicityVaccine, 2020
- Influence of Array Interspacing on the Force Required for Successful Microneedle Skin Penetration: Theoretical and Practical ApproachesJournal of Pharmaceutical Sciences, 2013
- The relative contributions of different skin layers to the mechanical behavior of human skin in vivo using suction experimentsMedical Engineering & Physics, 2005
- Force Modeling for Needle Insertion Into Soft TissueIEEE Transactions on Biomedical Engineering, 2004
- Stratum Corneum Biomechanical Properties I. Influence of Relative Humidity on Normal and Extracted Human Stratum CorneumJournal of Investigative Dermatology, 1971