The transient synchronization stability of converter is significantly influenced by controller limit mechanisms, especially when current and frequency limits are simultaneously activated. However, accurately analyzing such multi-limits switched system remains challenging, since current and frequency limits introduce discontinuous switching dynamics. To address this issue, a dynamic model with angle switching is established, and analytical switching rules of the system are derived. Based on the proposed model, a piece-wise transient energy function (TEF) is developed to analytically evaluate the stability of multi-limits switched system. Compared with conventional segmented equal area criteria (SEAC) methods, the proposed approach explicitly incorporates the combined effects of current limit, frequency limit, leading to less conservative and more physically interpretable stability characterization. In addition, it is shown that the activation of frequency limit introduces an inherent energy dissipation effect. Motivated by this observation, a practical frequency limit configuration method is derived, providing a direct analytical guideline for selecting frequency limiting parameters to ensure transient stability. Simulation studies under different limit settings and fault conditions validate the effectiveness of the proposed method, and hardware-in-loop experimental results further confirm its accuracy and practical applicability.