Determination of antimony, bismuth and tin in natural waters by flow injection solid phase extraction coupled with online hydride generation inductively coupled plasma mass spectrometry
- 20 December 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 28 (3) , 364-372
Abstract
A method was developed for the simultaneous separation, preconcentration and determination of antimony, bismuth and tin by flow injection solid phase extraction coupled with on-line hydride generation inductively coupled plasma mass spectrometry. The system is based on cationic retention of the analytes onto a mini-column filled with silica gel functionalised with 1,5-bis(di-2-pyridyl) methylene thiocarbonohydrazide placed in the injection valve of a simple flow manifold. The effects of chemicals and flow variables were investigated. The optimized operating conditions selected were: sample pH 3.5, sample flow rate 1.9 mL min−1, eluent flow rate 0.5 mL min−1, eluent 4% HNO3 and also 0.75% L-cysteine was added directly to the standard and sample solutions. The relative standard deviations (n = 10) were 1.4% for Sb, 1.1% for Bi and 1.5% for Sn. The enrichment factors were 7.0, 8.6 and 2.5 for Sb, Bi and Sn, respectively. Detection limits (3 min sample loading time) were 0.011 μg L−1 for Sb, 0.002 μg L−1 for Bi and 0.142 μg L−1 for Sn. The accuracy of the proposed method was checked with two certified reference materials (CRMs) of natural water TMDA-54.4 and TM-24.3. The results obtained using this method were in good agreement with the certified values of standard reference materials. The recoveries for the method when applied to determine traces of analytes in seawater were 97.0–107.5%.Keywords
This publication has 39 references indexed in Scilit:
- Simultaneous generation of hydrides of bismuth, lead and tin in the presence of ferricyanide and application to determination in biominerals by ICP-AESJournal of Analytical Atomic Spectrometry, 2010
- How reliable are environmental data on ‘orphan’ elements? The case of bismuth concentrations in surface watersJournal of Environmental Monitoring, 2009
- Determination of trace element concentrations in natural freshwaters: How low is “low”, and how low do we need to go?Journal of Environmental Monitoring, 2009
- Determination of bismuth and cadmium after solid-phase extraction with chromosorb-107 in a syringeAnalytica Chimica Acta, 2004
- Possibilities and limits of the simultaneous determination of As, Bi, Ge, Sb, Se, and Sn by flow injection–hydride generation–inductively coupled plasma–time-of-flight mass spectrometry (FI–HG–ICP–TOFMS)Analytica Chimica Acta, 2003
- Processes controlling trace element geochemistry of Arabian Sea sediments during the last 25,000 yearsGlobal and Planetary Change, 2000
- Effect of cysteine on the speciation of arsenic by using hydride generation atomic absorption spectrometryAnalytica Chimica Acta, 1994
- Preconcentration and selective determination of traces of tin in natural watersMicrochimica Acta, 1991
- Reduction of interferences in the determination of germanium by hydride generation and atomic emission spectrometryAnalytica Chimica Acta, 1990
- Determination of tin in environmental samples by graphite furnace atomic absorption and inductively coupled plasma-mass spectrometryAnalytical and Bioanalytical Chemistry, 1988