Abstract
With the recent extensive application of hydraulic fracturing to unconventional reservoirs, the detection and monitoring of hydraulic fractures has become increasingly important in the oil and gas industry. Electromagnetic methods that utilize an energized casing is one economic way to detect proppants designed to induce fractures because both transmitter and receiver are deployed on the surface, as shown in Figure 1. The proppant pumped into the fractures is made of highly conductive material to enhance the contrast of electrical conductivities between the fractures and host media [1]. The change in measured surface electromagnetic fields before and after hydraulic fracturing can be used to monitor the induced fractures in the deep subsurface. Very low frequency electric current sources are employed to ensure the appearance of detectable changes at the surface.