Longitudinal Studies of Cardiac Troponin-I Concentrations in Serum from Male Sprague Dawley Rats: Baseline Reference Ranges and Effects of Handling and Placebo Dosing on Biological Variability
Open Access
- 21 August 2009
- journal article
- research article
- Published by SAGE Publications in Toxicologic Pathology
- Vol. 37 (6) , 754-760
Abstract
Serum cardiac troponin-I has been validated as a biomarker for cardiotoxicity in numerous animal models; however, baseline reference ranges for cTnI concentration in a healthy population of laboratory rats, as well as an investigation of biological cTnI variability in rats with respect to time, handling, and placebo dosing methods, have not been reported. In this study, we used an ultrasensitive cTnI immunoassay to quantify hourly concentrations of cTnI in live rats handled under standard laboratory conditions using 15 μL of serum per determination. The baseline reference range (mean 4.94 pg/mL, range 1–15 pg/mL, 99% confidence interval [CI]) of cTnI concentration in rats was consistent with previously reported reference ranges for cTnI in humans (1–12 pg/mL) and with preliminary studies in dogs (1–4 pg/mL) and monkeys (4–5 pg/mL) using the same cTnI assay method. In addition, cTnI concentrations in individual rat serum samples show minimal biological variability over a twenty-four-hour interval when compared to a meaningful reference change value of 193% to 206%. Furthermore, measurements of cTnI concentration were consistent within the reference limits in individual rats over long periods and under three different standard laboratory handling conditions. Thus, using this new method, rats can be followed longitudinally at hourly intervals, and a doubling of cTnI concentration would be significant above biological variability. This is a new paradigm for preclinical testing, which allows transient changes in cTnI concentration to be accurately quantified. This understanding of baseline and biological variability in rats will be fundamental for designing and analyzing future studies that assess potential cardiotoxicity in drug development.Keywords
This publication has 17 references indexed in Scilit:
- A translational approach to detecting drug-induced cardiac injury with cardiac troponins: Consensus and recommendations from the Cardiac Troponins Biomarker Working Group of the Health and Environmental Sciences InstituteAmerican Heart Journal, 2009
- Analytical Characteristics of Commercial Cardiac Troponin I and T Immunoassays in Serum from Rats, Dogs, and Monkeys with Induced Acute Myocardial InjuryClinical Chemistry, 2008
- High fat diet-fed obese rats are highly sensitive to doxorubicin-induced cardiotoxicityToxicology and Applied Pharmacology, 2008
- Cardiac troponin is the most effective translational safety biomarker for myocardial injury in cardiotoxicityToxicology, 2008
- National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Use of Cardiac Troponin and B-Type Natriuretic Peptide or N-Terminal proB-Type Natriuretic Peptide for Etiologies Other than Acute Coronary Syndromes and Heart FailureClinical Chemistry, 2007
- In vitro and in vivo examination of cardiac troponins as biochemical markers of drug-induced cardiotoxicityToxicology, 2007
- An integrated microdialysis rat model for multiple pharmacokinetic/pharmacodynamic investigations of serotonergic agentsJournal of Pharmacological and Toxicological Methods, 2007
- Blood cardiac troponin in toxic myocardial injury: archetype of a translational safety biomarkerExpert Review of Molecular Diagnostics, 2006
- Reference Change Values for Brain Natriuretic Peptides RevisitedClinical Chemistry, 2006
- Myocardial infarction redefined—a consensus document of The Joint European Society of Cardiology/American College of Cardiology committee for the redefinition of myocardial infarctionJACC, 2000