Contrast medium injection protocol adjusted for body surface area in combined PET/CT
- 20 February 2013
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 23 (7) , 1970-1977
Abstract
To evaluate the effect of contrast medium dose adjustment for body surface area (BSA) compared with a fixed-dose protocol in combined positron emission tomography (PET) and computed tomography (CT) (PET/CT). One hundred and twenty patients were prospectively included for 18F-2-deoxy-fluor-glucose (18F-FDG)-PET/CT consisting of a non-enhanced and a venous contrast-enhanced CT, both used for PET attenuation correction. The first 60 consecutive patients received a fixed 148-ml contrast medium dose. The second 60 patients received a dose that was based on their calculated BSA. Mean and maximum standardised FDG uptake (SUVmean and SUVmax) and contrast enhancement (HU) were measured at multiple anatomical sites and PET reconstructions were evaluated visually for image quality. A decrease in the variance of contrast enhancement in the BSA group compared with the fixed-dose group was seen at all anatomical sites. Comparison of tracer uptake SUVmean and SUVmax between the fixed and the BSA group revealed no significant differences at all anatomical sites (all P > 0.05). Comparison of the overall image quality scores between the fixed and the BSA group showed no significant difference (P = 0.753). BSA adjustment results in increased interpatient homogeneity of contrast enhancement without affecting PET values. In combined PET/CT, a BSA adjusted contrast medium protocol should be used preferably. • Intravenous contrast medium is essential for many applications of PET/CT • Body surface area adjustment of contrast medium helps standardise contrast enhancement • Underdosing or overdosing of contrast medium will be reduced • PET image quality is not influenced • BSA adjusted contrast medium protocol should be used preferably in combined PET/CTKeywords
This publication has 24 references indexed in Scilit:
- PET/CT in lung cancer: Influence of contrast medium on quantitative and clinical assessmentEuropean Radiology, 2012
- Contrast timing in computed tomography: Effect of different contrast media concentrations on bolus geometryEuropean Journal of Radiology, 2012
- Effect of different saline chaser volumes and flow rates on intravascular contrast enhancement in CT using a circulation phantomEuropean Journal of Radiology, 2010
- Value of contrast-enhanced multiphase CT in combined PET/CT protocols for oncological imagingBritish Journal of Radiology, 2007
- Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi–Detector Row CT?Radiology, 2007
- Low dose non-enhanced CT versus standard dose contrast-enhanced CT in combined PET/CT protocols for staging and therapy planning in non-small cell lung cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2006
- Contrast-Induced NephropathyAmerican Journal of Roentgenology, 2004
- Use of high concentration contrast media: principles and rationale—vascular districtEuropean Journal of Radiology, 2003
- Body surface area prediction in normal-weight and obese patientsAmerican Journal of Physiology-Endocrinology and Metabolism, 2001