Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery
Authors:
Open Access
- 23 November 2011
- journal article
- research article
- Published by Elsevier in British Journal of Anaesthesia
- Vol. 108 (1) , 108-115
Abstract
Dynamic variables reliably predict fluid responsiveness (FR) in adults, but no data are available regarding their performance in infants. The aim of this prospective study was to assess whether pulse pressure variation (PPV) and stroke volume variation (SVV), in contrast to central venous pressure (CVP) and global end-diastolic volume (GEDV), are applicable in infants undergoing congenital heart surgery and to assess threshold values that may help to guide fluid administration in these patients. Twenty-six anaesthetized infants, mean (sd) weight 9.7 (4.3) kg, were studied during closed-chest conditions and changing loading conditions before and after repair of congenital heart disease. Stroke volume index was measured by transoesophageal echocardiography (SVITOE), CVP was measured via a central venous line, GEDV index (GEDVI) was measured by transpulmonary thermodilution, and PPV and SVV were monitored using the PiCCO monitoring system. Fifteen infants had increased SVITOE with fluid loading ≥15% (responders); 11 infants were defined as non-responders. Analysing the relationship between CVP, GEDVI, SVV, and PPV at baseline with volume-induced percentage change in SVITOE, only PPV was significantly correlated with ΔSVITOE both before (r=0.54, P=0.004) and after (r=0.73, P>0.0001). As assessed by receiver-operating characteristic curve analysis, only PPV accurately predicted FR before surgical repair [area under the curve (AUC): 0.79, P=0.01] and after surgical repair (AUC: 0.86, P=0.002). PPV, in contrast to SVV, CVP, and GEDVI, predicted FR in infants undergoing congenital heart surgery both before and after repair of congenital heart disease.Keywords
Funding Information
- institutional departmental sources
This publication has 34 references indexed in Scilit:
- Effects of norepinephrine on dynamic variables of fluid responsiveness during hemorrhage and after resuscitation in a pediatric porcine modelPediatric Anesthesia, 2009
- Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal modelActa Anaesthesiologica Scandinavica, 2008
- Respiratory Variations in Pulse Oximetry Plethysmographic Waveform Amplitude to Predict Fluid Responsiveness in the Operating RoomAnesthesiology, 2007
- Stroke Volume and Pulse Pressure Variation for Prediction of Fluid Responsiveness in Patients Under oing Off-Pump Coronary Artery Bypass GraftingChest, 2005
- Changes in Arterial Pressure during Mechanical VentilationAnesthesiology, 2005
- Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjectsCritical Care Medicine, 2004
- Predicting Fluid Responsiveness in ICU PatientsChest, 2002
- Reliability of a new algorithm for continuous cardiac output determination by pulse-contour analysis during hemodynamic instabilityCritical Care Medicine, 2002
- Use of transesophageal Doppler ultrasonography in ventilated pediatric patients: Derivation of cardiac outputCritical Care Medicine, 2000
- Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilutionIntensive Care Medicine, 2000