Percutaneous Endoscopic Gastrostomy Evaluation of Device Materials: Are We “Failsafe”?
Authors:
- 1 December 2005
- journal article
- review article
- Published by Wiley in Nutrition in Clinical Practice
- Vol. 20 (6) , 613-617
Abstract
The development of the percutaneous endoscopic gastrostomy (PEG) tube for enteral access was a revolutionary technological advance. This device has undergone some minor modification over the past 30 years but remains very similar to the original PEG tube design. Use of the PEG tube for gastric enteral feeding access continues to increase yearly both in pediatric and adult populations. One of the difficulties noted with PEG tube use in daily clinical practice is the ultimate degradation of the PEG tube wall material, leading to tube cracking, tearing, and leaking, requiring replacement of the gastrostomy tube. Historically, the predominant polymer material used for PEG tube composition was silicone. More recently, polyurethane has been examined as a potential, more durable material for PEG tube composition. Copolymers, or combinations of silicone and polyurethane and other polymer materials, are currently under investigation as the answer for the development of a bioinert, tissue‐friendly, durable, PEG tube composition material.Keywords
This publication has 11 references indexed in Scilit:
- Degradation of Polyurethane Gastrostomy Devices: What Is the Role of Fungal Colonization?Digestive Diseases and Sciences, 2005
- Dwell time and functional failure in percutaneous endoscopic gastrostomy tubes: a prospective randomized‐controlled comparison between silicon polymer and polyurethane percutaneous endoscopic gastrostomy tubesAlimentary Pharmacology & Therapeutics, 2004
- Longevity of silicone and polyurethane catheters in long‐term enteral feeding via percutaneous endoscopic gastrostomyAlimentary Pharmacology & Therapeutics, 2003
- Isolation and identification of biofilm microorganisms from silicone gastrostomy devicesJournal of Pediatric Surgery, 2003
- Inhibition of bacterial and leukocyte adhesion under shear stress conditions by material surface chemistryJournal of Biomaterials Science, Polymer Edition, 2003
- Typing and Subtyping of 83 Clinical Isolates Purified from Surgically Implanted Silicone Feeding Tubes by Random Amplified Polymorphic DNA AmplificationJournal of Clinical Microbiology, 2002
- A randomized trial of polyurethane and silicone percutaneous endoscopic gastrostomy cathetersAlimentary Pharmacology & Therapeutics, 2000
- Review: microbiology of the gastrostomy tube.Journal of the American College of Nutrition, 1994
- Intraluminal fungal colonization of gastrostomy tubesGastrointestinal Endoscopy, 1993
- Gastrostomy without laparotomy: A percutaneous endoscopic techniqueJournal of Pediatric Surgery, 1980