Abstract
OBJECTIVE: Simultaneous integrated boost(SIB) is a hypo-fractionation technique wherein the tumor receives different doses to different areas in a single fraction. In our study, we have evaluated the dosimetric feasibility of SIB in the treatment of malignant gliomas and compared the SIB plans of VMAT and IMRT. METHODOLOGY: The patient’s MRI (taken four weeks after surgery) and planning CT were used for generating SIB plans with VMAT and IMRT. GPTV is defined as the tumor edema in FLAIR plus a margin of 5 mm. CPTV is defined as the GPTV plus a margin of 2 cm. A dose of 2Gy per fraction was prescribed to the CPTV and 2.4Gy to the GPTV for a total of 25 fractions. The plans were accepted only if they met the set of planning objectives defined in the protocol. The feasibility of SIB planning was evaluated, and the dosimetric data of VMAT and IMRT for SIB planning was compared. Results: The GPTV coverage was significantly better in VMAT than in IMRT (98.67% vs 98.19%;p=0.024). The conformity index for GPTV in IMRT was higher than that of VMAT (0.83 vs 0.76; p=0.001). In contrast to what observed in GPTV, the percentage coverage of CPTV was better in IMRT (97.88% vs 96.87%; p=0.021). But the conformity index of CPTVannulus was higher in VMAT (0.72 vs 0.67; p=0.01). There was no difference in homogeneity index of GPTV and CPTV annulus between the plans. The mean dose received by Normal brain was higher in IMRT than in VMAT (28Gy vs 24.2Gy; p<0.001). Ipsilateral optic nerve has received lesser Dmax in IMRT (44.2Gy vs 46.95Gy; p=0.02). The Dmax of PRV brainstem was higher in VMAT (58Gy vs 57.3Gy; p=0.003). No difference was seen in Dmax of brainstem OAR, optic chiasm PRV and OAR, contralateral optic nerve, ipsilateral lens and cochleae. The treatment times and monitor units were significantly less in VMAT than in IMRT. CONCLUSION: SIB is dosimetrically feasible for hypofractionation in malignant gliomas using IMRT and VMAT. IMRT plans had better boost conformity, lower ipsilateral optic nerve and brainstem maximum doses compared to VMAT. Whereas, VMAT had better coverage, better overall PTV conformity, lower normal brain mean dose, lower monitor units and lesser treatment times. By giving dose constraints to the PRV rather than for OAR itself, the OAR doses can be further reduced while maintaining the PTV coverage. Although planning of VMAT is cumbersome and time consuming, the advantage of reducing treatment time is beneficial to the patients’ comfort and better managing of patient load in high volume centers.