Automated CT Perfusion Ischemic Core Volume and Noncontrast CT ASPECTS (Alberta Stroke Program Early CT Score)

Authors:

Abstract
Background and Purpose—: The semiquantitative noncontrast CT Alberta Stroke Program Early CT Score (ASPECTS) and RAPID automated computed tomography (CT) perfusion (CTP) ischemic core volumetric measurements have been used to quantify infarct extent. We aim to determine the correlation between ASPECTS and CTP ischemic core, evaluate the variability of core volumes within ASPECTS strata, and assess the strength of their association with clinical outcomes. Methods—: Review of a prospective, single-center database of consecutive thrombectomies of middle cerebral or intracranial internal carotid artery occlusions with pretreatment CTP between September 2010 and September 2015. CTP was processed with RAPID software to identify ischemic core (relative cerebral blood flowR =−0.36; P R =−0.42; P R =0.50; P P =0.01) and CTP core ≤50 cc (odds ratio 3.86; 95% confidence interval, 1.22–12.15; P =0.02) independently and comparably predictive of good outcome. Conclusions—: There is wide variability of CTP-derived core volumes within ASPECTS strata. Patient selection may be affected by the imaging selection method.

This publication has 15 references indexed in Scilit: