An electrochemiluminescence sensor for determination of durabolin based on CdTe QD films by layer-by-layer self-assembly
- 3 March 2011
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 400 (3) , 807-814
Abstract
This work reported for the first time the use of flow injection electrochemiluminescence (FI-ECL) sensor for the determination of durabolin in an aqueous system based on CdTe quantum dot (QD) films. Aqueous CdTe colloidal solutions were prepared using thioglycolic acid as a capping agent. Zetasizer Nano ZS (Malvern, UK) was employed to characterize the size of CdTe QDs. The UV–vis and photoluminescence spectra of samples were systematically characterized. Indium tin oxide (ITO) slide glass was modified with CdTe QDs by layer-by-layer self-assembly. CdTe QD films were packed into a homemade cell and used as a recognizer of the FI-ECL sensor to determine durabolin. The intensive anodic ECL emission was obtained at a starting potential of +1.3 V (vs. Ag/AgCl) in a carbonate bicarbonate buffer solution with a pH of 9.93 at an ITO electrode. The ECL intensity was correlated linearly with the concentration of durabolin over the range of 1.0 × 10−8–1.0 × 10−5 g mL−1, and the detection limit was 2.5 × 10−9 g mL−1. The relative standard deviation for the determination of 1.0 × 10−6 g mL−1 durabolin was 1.04% (n = 11). This simple and sensitive sensor revealed good reproducibility for ECL analysis. As a result, the new FI-ECL sensor had been successfully applied to the determination of durabolin in food samples. This strategy could be easily realized and opened new avenues for the applications of QDs in ECL biosensing. Figure This work reported for the first time the flow injection electrochemiluminescence (FI-ECL) sensor for the determination of durabolin in an aqueous system based on CdTe quantum dot (QD) films. Schematic diagram of the FI-CL system and the ECL cell was shown in online abstract figure.Keywords
This publication has 34 references indexed in Scilit:
- Science as art: self-assembly of hybrid SiO 2 -coated nanocrystalsCrystEngComm, 2010
- Identification of anabolic steroids and derivatives using bioassay-guided fractionation, UHPLC/TOFMS analysis and accurate mass database searchingAnalytica Chimica Acta, 2010
- Molecular Imprinting-Chemiluminescence Sensor for the Determination of AmoxicillinAnalytical Letters, 2010
- BSA activated CdTequantum dot nanosensor for antimony ion detectionThe Analyst, 2010
- Effect of substrate and embedded metallic impurities of fullerene in the determination of nandroloneAnalytica Chimica Acta, 2009
- Quantum Dot Electrochemiluminescence in Aqueous Solution at Lower Potential and Its Sensing ApplicationThe Journal of Physical Chemistry C, 2008
- Preparation and photoluminescence of water-dispersible ZnSe nanocrystalsMaterials Letters, 2004
- Nanoscale probes encapsulated by biologically localized embedding (PEBBLEs) for ion sensing and imaging in live cellsTalanta, 2004
- Determination of adrenaline by using inhibited Ru(bpy)32+ electrochemiluminescenceAnalytica Chimica Acta, 2002
- Anabolic-Androgenic Steroid Therapy in the Treatment of Chronic DiseasesThe Journal of Clinical Endocrinology & Metabolism, 2001