Hepatic Arteries in Potential Donors for Living Related Liver Transplantation: Evaluation with Multi–Detector Row CT Angiography

Authors:
  • JBJae Ho Byun
    Jae Ho Byun
  • HHHyun Kwon Ha
    Hyun Kwon Ha
  • PKPyo Nyun Kim
    Pyo Nyun Kim
  • AKAh Young Kim
    Ah Young Kim
  • SLSung Gyu Lee
    Sung Gyu Lee
  • MLMoon-Gyu Lee
    Moon-Gyu Lee

Abstract
PURPOSE: To assess the accuracy of multi–detector row computed tomographic (CT) angiography in the evaluation of hepatic arterial anatomy in living related liver transplantation (LRLT) donors. MATERIALS AND METHODS: During a 10-month period, 62 potential LRLT donors were evaluated with CT and conventional angiography. Multi–detector row CT was performed after intravenous injection of 150 mL of contrast material at 3 mL/sec. CT angiograms of the hepatic arteries were generated by a radiologist who used volume rendering and maximum intensity projection techniques without knowledge of results of conventional angiography. Two reviewers reviewed CT and conventional angiograms retrospectively in consensus. The results of the two examinations were then compared. RESULTS: CT examinations were technically adequate in 56 (90%) donors. Respiratory motion artifact compromised detailed hepatic artery analysis in six donors (10%). Second-order branches of right hepatic arteries were visualized in 58 donors (94%), and s...