Dose conversion coefficients for photon exposure of the human eye lens
Authors:
- R BehrensRBR Behrens
- G DietzeGDG Dietze
- 22 December 2010
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (2) , 415-437
Abstract
In recent years, several papers dealing with the eye lens dose have been published, because epidemiological studies implied that the induction of cataracts occurs even at eye lens doses of less than 500 mGy. Different questions were addressed: Which personal dose equivalent quantity is appropriate for monitoring the dose to the eye lens? Is a new definition of the dose quantity H(p)(3) based on a cylinder phantom to represent the human head necessary? Are current conversion coefficients from fluence to equivalent dose to the lens sufficiently accurate? To investigate the latter question, a realistic model of the eye including the inner structure of the lens was developed. Using this eye model, conversion coefficients for electrons have already been presented. In this paper, the same eye model-with the addition of the whole body-was used to calculate conversion coefficients from fluence (and air kerma) to equivalent dose to the lens for photon radiation from 5 keV to 10 MeV. Compared to the values adopted in 1996 by the International Commission on Radiological Protection (ICRP), the new values are similar between 40 keV and 1 MeV and lower by up to a factor of 5 and 7 for photon energies at about 10 keV and 10 MeV, respectively. Above 1 MeV, the new values (calculated without kerma approximation) should be applied in pure photon radiation fields, while the values adopted by the ICRP in 1996 (calculated with kerma approximation) should be applied in case a significant contribution from secondary electrons originating outside the body is present.Keywords
This publication has 7 references indexed in Scilit:
- Inconsistencies in egspp (the EGSnrc C++ class library) and in the SLAB module of BEAMnrcPhysics in Medicine & Biology, 2010
- Monitoring the eye lens: which dose quantity is adequate?Physics in Medicine & Biology, 2010
- Dose conversion coefficients for electron exposure of the human eye lensPhysics in Medicine & Biology, 2009
- Risk of Cataract after Exposure to Low Doses of Ionizing Radiation: A 20-Year Prospective Cohort Study among US Radiologic TechnologistsAmerican Journal of Epidemiology, 2008
- Organ dose conversion coefficients for voxel models of the reference male and female from idealized photon exposuresPhysics in Medicine & Biology, 2007
- Cataracts among Chernobyl Clean-up Workers: Implications Regarding Permissible Eye ExposuresRadiation Research, 2007
- Dimensions of the human eye relevant to radiation protection (dosimetry)Physics in Medicine & Biology, 1975