Periprosthetic Osteolysis after Total Wrist Arthroplasty
- 17 May 2014
- journal article
- research article
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 03 (02) , 101-106
Abstract
Background and Literature Review Periprosthetic osteolysis (PPO) after second- or third-generation total wrist arthroplasty (TWA), with or without evident loosening of the implant components, has previously been reported in the literature, but rarely in a systematic way. Purpose The purpose of this study was to analyze the prevalence, location, and natural history of PPO following a TWA and to determine whether this was associated with prosthetic loosening. Patients and Methods We analyzed 44 consecutive cases in which a RE-MOTION TWA (Small Bone Innovations Inc., Morrisville, PA, USA) had been done. Results We found significant periprosthetic radiolucency (more than 2 mm in width) at the radial component side in 16 of the cases and at the carpal component side in 7. It developed gradually juxta-articularly around the prosthetic components regardless of the primary diagnosis, and seemed to stabilize in most patients after 1–3 years. In a small percentage of the patients, the periprosthetic area of bone resorption was markedly larger. In general, radiolucency was not related to evident loosening of the implant components, and only five carpal components and one radial had subsided or tilted. Conclusion Periprosthetic loosening is frequent following a TWA. In our series it was not necessarily associated with implant loosening and seemed to stabilize within 3 years. Close and continued observation is, however, recommended. Level of Evidence Therapeutic IVKeywords
This publication has 27 references indexed in Scilit:
- Favorable results after total wrist arthroplastyActa Orthopaedica, 2013
- High rate of complications and radiographic loosening of the biaxial total wrist arthroplasty in rheumatoid arthritisActa Orthopaedica, 2011
- History and Systematic Review of Wear and Osteolysis Outcomes for First-generation Highly Crosslinked PolyethyleneClinical Orthopaedics and Related Research, 2011
- Universal Total Wrist Arthroplasty: Midterm Follow-Up StudyThe Journal of Hand Surgery, 2011
- Wear Rate of Highly Cross-Linked Polyethylene in Total Hip ArthroplastyJournal of Bone and Joint Surgery, 2009
- Die BIAX-Handgelenkprothese: Management und Erfahrungen bei 42 PatientenHandchirurgie · Mikrochirurgie · Plastische Chirurgie, 2007
- Wear-Induced Osteolysis and Synovial Swelling in a Patient With a Metal–Polyethylene Wrist ProsthesisThe Journal of Hand Surgery, 2006
- Results of biaxial total wrist arthroplasty with a modified (long) metacarpal stemThe Journal of Hand Surgery, 2003
- RELATIONSHIP BETWEEN POLYETHYLENE WEAR AND OSTEOLYSIS IN HIPS WITHA SECOND-GENERATION POROUS-COATED CEMENTLESS CUP AFTER SEVEN YEARS OF FOLLOW-UPJournal of Bone and Joint Surgery, 2003
- Total Wrist Arthroplasty in Rheumatoid Arthritis; A Long Term Clinical ReviewClinical Orthopaedics and Related Research, 1997