CCAT: Magnetic Sensitivity Measurements of Kinetic Inductance Detectors
Open Access
- 11 February 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Abstract
The CCAT Observatory is a ground-based submillimeter to millimeter experiment located on Cerro Chajnantor in the Atacama Desert, at an altitude of 5,600 meters. CCAT features the 6-meter Fred Young Submillimeter Telescope (FYST), which will cover frequency bands from 210 GHz to 850 GHz using its first-generation science instrument, Prime-Cam. The detectors used in Prime-Cam are feedhorn-coupled, lumped-element superconducting microwave kinetic inductance detectors (KIDs). The telescope will perform wide-area surveys at speeds on the order of degrees per second. During telescope operation, the KIDs are exposed to changes in the magnetic field caused by the telescope's movement through Earth's magnetic field and internal sources within the telescope. We present and compare measurements of the magnetic sensitivity of three different CCAT KID designs at 100 mK. The measurements are conducted in a dilution refrigerator (DR) with a set of room temperature Helmholtz coils positioned around the DR. We discuss the implications of these results for CCAT field operations.Keywords
All Related Versions
Funding Information
- Cornell University
- Canada Foundation for Innovation and the Provinces of Ontario
- German Science Foundation for the construction of the FYST telescope (INST216/733-1 FUGG)
- NSF
- construction of EoR-Spec (AST-2009767)
- NSF for the construction of the 350 GHz instrument module for Prime-Cam (AST-2117631)
- National Science Foundation (2503181)
- National Science Foundation (INST 216/733-1)
- National Science Foundation (AST-2009767)
- National Science Foundation (AST-2117631)
- National Science Foundation (2503181)
This publication has 22 references indexed in Scilit:
- Magnetic field tunable spectral response of kinetic inductance detectorsApplied Physics Letters, 2025
- The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing ModuleJournal of Low Temperature Physics, 2022
- CCAT-Prime: Characterization of the First 280 GHz MKID Array for Prime-CamJournal of Low Temperature Physics, 2022
- Small Aperture Telescopes for the Simons ObservatoryJournal of Low Temperature Physics, 2020
- Design and Performance of the First BICEP Array ReceiverJournal of Low Temperature Physics, 2020
- Magnetic field dependence of the internal quality factor and noise performance of lumped-element kinetic inductance detectorsApplied Physics Letters, 2016
- Kinetic inductance magnetometerNature Communications, 2014
- Proximity-coupled Ti/TiN multilayers for use in kinetic inductance detectorsApplied Physics Letters, 2013
- Operation of a titanium nitride superconducting microresonator detector in the nonlinear regimeJournal of Applied Physics, 2013
- An analysis method for asymmetric resonator transmission applied to superconducting devicesJournal of Applied Physics, 2012