Clinical experience and two-year follow-up with a one-piece viscoelastic cervical total disc replacement
- 1 December 2017
- journal article
- Published by AME Publishing Company in Journal of Spine Surgery
- Vol. 3 (4) , 630-640
Abstract
Background: The purpose of this study is to present clinical outcome data from a 2-year post-market study of a viscoelastic one-piece cervical total disc replacement (TDR) in Europe. Methods: Thirty-nine patients were implanted at five surgical sites in an European post-market clinical study. Clinical outcomes included improvement of neck disability index (NDI) and visual analog scale scores for neck and arm pain from baseline to 2-year follow-up, neurological examinations, patients view on the success of surgery, complications, and subsequent surgical interventions. Results: Thirty patients had the Freedom® Cervical Disc (FCD) implanted at a single level, and nine patients were implanted at two adjacent levels. The population had a similar distribution of male [20] and female [19] subjects, with a mean age of 45 years. All self-administered outcome measures showed significant clinically important improvements from baseline to the 2-year follow-up. Mean preoperative NDI score improved from 48% to 20%, 13%, 8%, 6% and 4% at 6 weeks, 3, 6, 12, and 24 months, respectively. Average preoperative visual analog scale (VAS) scores of the neck, right and left arm pain intensity and frequency showed significant improvement. All neurological outcome measurements showed immediate improvement from preoperative values and continued improvement throughout 2 years follow-up. From pre-op to 24 months, neurological deficits declined in the population from 21% to 6% for reflex function, 62% to 17% for sensory function, and 38% to 3% for motor function. No patients experienced a deterioration in any measured outcomes compared with the preoperative situation. Patient satisfaction increased over 2 years post-op, with 83% of patients responding that they would “definitely” choose to have the same treatment for their neck/arm condition and another 11% responding that they would “probably” choose to have the same treatment. Conclusions: The FCD performs as expected in patients with single-level and two-level degenerative disc disease.Keywords
This publication has 42 references indexed in Scilit:
- Cervical disc arthroplasty with the Prestige LP disc versus anterior cervical discectomy and fusion, at 2 levels: results of a prospective, multicenter randomized controlled clinical trial at 24 monthsJournal of Neurosurgery: Spine, 2017
- Comparison of Outcomes of Single-Level Anterior Cervical Discectomy With Fusion and Single-Level Artificial Cervical Disc Replacement for Single-Level Cervical Degenerative Disc DiseaseSpine, 2017
- Wear assessments of a new cervical spinal disk prosthesis: Influence of loading and kinematic patterns during in vitro wear simulationProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2015
- Cervical artificial disc replacement with ProDisc-C: Clinical and radiographic outcomes with long-term follow-upJournal of Clinical Neuroscience, 2014
- Is Cervical Disc Arthroplasty Superior to Fusion for Treatment of Symptomatic Cervical Disc Disease? A Meta-AnalysisClinical Orthopaedics and Related Research, 2013
- A Meta-Analysis Comparing the Results of Cervical Disc Arthroplasty with Anterior Cervical Discectomy and Fusion (ACDF) for the Treatment of Symptomatic Cervical Disc DiseaseJournal of Bone and Joint Surgery, 2013
- ProDisc-C and Anterior Cervical Discectomy and Fusion as Surgical Treatment for Single-Level Cervical Symptomatic Degenerative Disc DiseaseSpine, 2013
- Results of the prospective, randomized, controlled multicenter Food and Drug Administration investigational device exemption study of the ProDisc-C total disc replacement versus anterior discectomy and fusion for the treatment of 1-level symptomatic cervical disc diseaseThe Spine Journal, 2009
- Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral discJournal of Biomechanics, 2006
- The Neck Disability Index: a study of reliability and validity.1991