Static Magnetic Fields Affect Capillary Flow of Red Blood Cells in Striated Skin Muscle
- 26 January 2008
- journal article
- Published by Wiley in Microcirculation
- Vol. 15 (1) , 15-26
Abstract
Blood flowing in microvessels is one possible site of action of static magnetic fields (SMFs). We evaluated SMF effects on capillary flow of red blood cells (RBCs) in unanesthetized hamsters, using a skinfold chamber technique for intravital fluorescence microscopy. By this approach, capillary RBC velocities (vRBC), capillary diameters (D), arteriolar diameters (Dart), and functional vessel densities (FVD) were measured in striated skin muscle at different magnetic flux densities. Exposure above a threshold level of about 500 mT resulted in a significant (P < 0.001) reduction of vRBC in capillaries as compared to the baseline value. At the maximum field strength of 587 mT, vRBC was reduced by more than 40%. Flow reduction was reversible when the field strength was decreased below the threshold level. In contrast, mean values determined at different exposure levels for the parameters D, Dart, and FVD did not vary by more than 5%.Blood flow through capillary networks is affected by strong SMFs directed perpendicular to the vessels. Since the influence of SMFs on blood flow in microvessels directed parallel to the field as well as on collateral blood supply could not be studied, our findings should be carefully interpreted with respect to the setting of safety guidelines.Keywords
This publication has 25 references indexed in Scilit:
- Physical interactions of static magnetic fields with living tissuesProgress in Biophysics and Molecular Biology, 2005
- Regulation of Blood Flow in the MicrocirculationMicrocirculation, 2005
- More research is needed to determine the safety of static magnetic fieldsProgress in Biophysics and Molecular Biology, 2004
- Influence of the Endothelial Glycocalyx on Cerebral Blood Flow in MiceJournal of Cerebral Blood Flow & Metabolism, 2000
- NMR “diffusion‐diffraction” of water revealing alignment of erythrocytes in a magnetic field and their dimensions and membrane transport characteristicsMagnetic Resonance in Medicine, 1997
- Cap Image - ein neuartiges computerunterstütztes Videobildanalysesystem für die dynamische Kapillarmikroskopie - Cap Image - A Newly-developed Computer-aided Videoframe Analysis System for Dynamic CapillaroscopyBiomedical Engineering / Biomedizinische Technik, 1997
- Beeinflussen starke statische Magnetfelder in der NMR-Tomographie die Gewebedurchblutung?RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1991
- Induced Alignment of Flowing Sickle Erythrocytes in a Magnetic Field A Preliminary ReportInvestigative Radiology, 1985
- Technical report—a new chamber technique for microvascular studies in unanesthetized hamstersZeitschrift für Die Gesamte Experimentelle Medizin, 1980
- Orientation of Sickled Erythrocytes in a Magnetic FieldNature, 1965