Stiffness and ultimate load of osseointegrated prosthesis fixations in the upper and lower extremity
Open Access
- 1 January 2013
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 12 (1) , 70
Abstract
Techniques for the skeletal attachment of amputation-prostheses have been developed over recent decades. This type of attachment has only been performed on a small number of patients. It poses various potential advantages compared to conventional treatment with a socket, but is also associated with an increased risk of bone or implant-bone interface fracture in the case of a fall. We therefore investigated the bending stiffness and ultimate bending moment of such devices implanted in human and synthetic bones. Eight human specimens and 16 synthetic models of the proximal femora were implanted with lower extremity prostheses and eight human specimens and six synthetic humeri were implanted with upper extremity prostheses. They were dissected according to typical amputation levels and underwent loading in a material testing machine in a four-point bending setup. Bending stiffness, ultimate bending moment and fracture modes were determined in a load to failure experiment. Additionally, axial pull-out was performed on eight synthetic specimens of the lower extremity. Maximum bending moment of the synthetic femora was 160.6±27.5 Nm, the flexural rigidity of the synthetic femora was 189.0±22.6 Nm2. Maximum bending moment of the human femora was 100.4±38.5 Nm, and the flexural rigidity was 137.8±29.4 Nm2. The maximum bending moment of the six synthetic humeri was 104.9±19.0 Nm, and the flexural rigidity was 63.7±3.6 Nm2. For the human humeri the maximum bending moment was 36.7±11.0 Nm, and the flexural rigidity at was 43.7±10.5 Nm2. The maximum pull-out force for the eight synthetic femora was 3571±919 N. Significant differences were found between human and synthetic specimens of the lower and upper extremity regarding maximum bending moment, bending displacement and flexural rigidity. The results of this study are relevant with respect to previous finding regarding the load at the interfaces of osseointegrated prosthesis fixation devices and are crucial for the development of safety devices intended to protect the bone-implant interface from damaging loadings.Keywords
This publication has 23 references indexed in Scilit:
- Periprosthetic bone mineral density changes after unicondylar knee arthroplastyThe Knee, 2013
- Implantation der Endo-Exo-Femurprothese zur Verbesserung der Mobilität amputierter PatientenOperative Orthopädie und Traumatologie, 2011
- Osseointegrated Titanium Implants for Limb Prostheses Attachments: Infectious ComplicationsClinical Orthopaedics and Related Research, 2010
- A Comparative Finite-Element Analysis of Bone Failure and Load Transfer of Osseointegrated Prostheses FixationsAnnals of Biomedical Engineering, 2010
- Mechanical Evaluation of Large-Size Fourth-Generation Composite Femur and Tibia ModelsAnnals of Biomedical Engineering, 2010
- The Safety of C-Leg: Biomechanical TestsJPO Journal of Prosthetics and Orthotics, 2009
- Structural properties of fourth-generation composite femurs and tibiasJournal of Biomechanics, 2008
- Precision of dual energy x-ray absorptiometry in the upper extremitiesBone and Mineral, 1993
- Osseointegration and its experimental backgroundThe Journal of Prosthetic Dentistry, 1983
- Bite force and oral function in patients with osseointegrated oral implantsEuropean Journal of Oral Sciences, 1977