Abstract
Target impedance plays a critical role in guiding a robust power delivery network (PDN) design. However, the traditional methodology has difficulty in associating time domain information, such as current profile and voltage drop constraints, with frequency domain PDN impedance. Existing works try to derive frequency-dependent target impedance, but the average voltage drop is not explicitly taken into account, and the dynamic voltage drop constraints are not considered separately in middle and high-frequency ranges. Such limitations can result in under-or over-designed PDN. This paper proposes a frequency-dependent target impedance methodology, which determines the target impedance shape from the given constraints in multiple frequency ranges. The key idea is to exploit a concept of magnitude equivalent frequency (MEF) to bridge the time domain behavior and frequency domain target impedance. Experiment results show that the proposed frequency-dependent target impedance tightly satisfies the given voltage drop constraints.

This publication has 14 references indexed in Scilit: