Stability of connected mini-implants and miniplates for skeletal anchorage in orthodontics
Open Access
- 4 May 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 30 (5) , 483-489
Abstract
The aim of this study was to examine the primary stability of connected mini-implants and miniplates. Three different skeletal anchorage systems were investigated: (1) two 1.5 mm diameter cylindrical mini-implants connected with a 0.021 × 0.025 inch stainless steel (SS) wire, (2) two 1.6 mm diameter tapered mini-implants connected with a 0.021 × 0.025 inch SS wire, and (3) two 2.0 mm diameter cylindrical mini-implants connected by a titanium locking miniplate. Fifteen standardized bovine bone specimens were prepared, five specimens for each experimental group. The connected mini-implants were fixed on the bone specimens. The systems underwent uniaxial pull-out tests at the midpoint of the connecting wire or miniplate using a mechanical testing machine. One-way analysis of variance was used to determine the difference of the pull-out test results between the groups. Both the titanium miniplate and SS wire connection systems showed severe deformation at the screw head, which broke before the mini-implants failed. The 2.0 mm miniplate system showed the highest pull-out force (529 N) compared with the other two wire connection systems (P < 0.001). The 2.0 mm system was also stiffer than the 1.6 and 1.5 mm systems (P < 0.001). The yield force of the 2.0 mm miniplate (153 N) was significantly higher than the 1.5 mm (88 N) and 1.6 mm (76 N) systems (P < 0.001). This in vitro study demonstrated that the connection of two mini-implants with a miniplate resulted in higher pull-out force, stiffness, and yield force to resist pulling force and deformation. Such a set-up could thus provide a stable system for orthodontic skeletal anchorage.Keywords
This publication has 14 references indexed in Scilit:
- Factors affecting the clinical success of screw implants used as orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2006
- Initial Results Regarding Force Exertion during Rapid Maxillary Expansion in ChildrenJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2006
- Interrelationship of trabecular mechanical and microstructural properties in sheep trabecular boneJournal of Biomechanics, 2005
- Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorageAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Principle and stability of locking platesThe Keio Journal of Medicine, 2003
- New innovations in craniomaxillofacial fixation: the 2.0 lock system.The Keio Journal of Medicine, 2003
- Orthodontic adhesives and bond strengthtestingSeminars in Orthodontics, 1997
- IMMEDIATE LOADING OF BRÅNEMARK IMPLANTS IN EDENTULOUS MANDIBLESImplant Dentistry, 1997
- Mechanical analysis of maxillofacial miniplatesBritish Journal of Oral and Maxillofacial Surgery, 1995
- Comparison of the resistance of miniplates and microplates to various in vitro forcesJournal of Oral and Maxillofacial Surgery, 1994