A field camera for MR sequence monitoring and system analysis
Open Access
- 14 May 2015
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 75 (4) , 1831-1840
Abstract
Purpose: MR image formation and interpretation relies on highly accurate dynamic magnetic fields of high fidelity. A range of mechanisms still limit magnetic field fidelity, including magnet drifts, eddy currents, and finite linearity and stability of power amplifiers used to drive gradient and shim coils. Addressing remaining errors by means of hardware, sequence, or signal processing optimizations, calls for immediate observation by magnetic field monitoring. The present work presents a stand‐alone monitoring system delivering insight into such field imperfections for MR sequence and system analysis.Methods: A flexible NMR field probe‐based stand‐alone monitoring system, built on a software‐defined‐radio approach, is introduced and used to sense field dynamics up to third‐order in space in a selection of situations with different time scales.Results: Highly sensitive trajectories are measured and successfully used for image reconstruction. Further field perturbations due to mechanical oscillations and thermal field drifts following demanding gradient use and external interferences are studied.Conclusion: A flexible and versatile monitoring system is presented, delivering camera‐like access to otherwise hardly accessible field dynamics with nanotesla resolution. Its stand‐alone nature enables field analysis even during unknown MR system states. Magn Reson Med 75:1831–1840, 2016. © 2015 Wiley Periodicals, Inc.Keywords
Funding Information
- Swiss Commission for Technology and Innovation (KTI 13756.1 PFFLM-NM)
This publication has 20 references indexed in Scilit:
- Pure phase encode magnetic field gradient monitorJournal of Magnetic Resonance, 2009
- A transmit/receive system for magnetic field monitoring of in vivo MRIMagnetic Resonance in Medicine, 2009
- Compensation of gradient-induced magnetic field perturbationsJournal of Magnetic Resonance, 2008
- NMR probes for measuring magnetic fields and field dynamics in MR systemsMagnetic Resonance in Medicine, 2008
- Spatiotemporal magnetic field monitoring for MRMagnetic Resonance in Medicine, 2008
- Detection and correction of frequency instabilities for volumetric 1H echo‐planar spectroscopic imagingMagnetic Resonance in Medicine, 2005
- Comments on ?Gradient-Induced Acoustic and Magnetic Field Fluctuations in a 4T Whole-Body MR Imager?Magnetic Resonance in Medicine, 2001
- Fully integrated probe for proton nuclear magnetic resonance magnetometryReview of Scientific Instruments, 2001
- Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systemsMagnetic Resonance in Medicine, 1991
- A Radiofrequency Spectrograph and Simple Magnetic-Field MeterReview of Scientific Instruments, 1950