Clinical application of Acoustic Radiation Force Impulse Imaging with Virtual Touch IQ in breast ultrasound: diagnostic performance and reproducibility of a new technique
- 19 July 2016
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 58 (2) , 140-147
Abstract
Background: Virtual Touch IQ (VTIQ) is a novel technique of quantitative sonoelastography that applies acoustic radiation force impulse (ARFI). Purpose: To evaluate breast ARFI imaging with VTIQ in the clinical setting, with regard to reproducibility and diagnostic performance, and to specify cutoff limits for the differentiation of benign and malignant lesions. Material and Methods: This retrospective study included 83 patients with 85 breast lesions (51 benign, 34 malignant) who received ARFI imaging with VTIQ. Two independent ARFI measurements of each lesion were performed and shear wave velocities (SWV) of the lesion and the adjacent tissues were measured. A lesion-to-fat velocity ratio (L/F Ratio) was calculated for each lesion. Diagnostic performance of SWV measurements and L/F Ratios was evaluated with receiver operating curve (ROC) analysis. The intraclass correlation coefficient and Bland–Altman plots were used to evaluate measurement reproducibility. Results: All measurements showed equal diagnostic performance, as measured by the area under the ROC curve (0.853 for SWV, 0.882 for the L/F Ratio). At a cutoff value of 3.23 m/s, sensitivity and specificity were 82.4% and 80.4%, respectively. An L/F Ratio cutoff value of 2.23 revealed a sensitivity and specificity of 89.7% and 76.5%. The reproducibility of the SWV measurements was moderate (limits of agreement, 40.3–44.4%) and higher than that of the L/F Ratios (54.5–60.2%). Conclusion: ARFI imaging with VTIQ is a novel, moderately reproducible, quantitative elastography technique, which provides useful information for the differentiation of benign and malignant breast lesions in the clinical setting.Keywords
This publication has 24 references indexed in Scilit:
- ShearWave™ Elastography BE1 Multinational Breast Study: Additional SWE™ Features Support Potential to Downgrade BI-RADS®-3 LesionsUltraschall in der Medizin - European Journal of Ultrasound, 2013
- Breast elasticity: Principles, technique, results: An update and overview of commercially available softwareEuropean Journal of Radiology, 2013
- Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 MassesRadiology, 2012
- Shear wave elastography for breast masses is highly reproducibleEuropean Radiology, 2011
- Breast Mass Evaluation: Factors Influencing the Quality of US ElastographyRadiology, 2011
- Ultrasonic Elastography in Breast Cancer DiagnosisAcademic Radiology, 2010
- Ultrasound is a useful adjunct to mammography in the assessment of breast tumours in all patientsInternational Journal Of Clinical Practice, 2009
- Breast Disease: Clinical Application of US Elastography for DiagnosisRadiology, 2006
- Elastography: Imaging the elastic properties of soft tissues with ultrasoundJournal of Medical Ultrasonics, 2002
- Diagnosis of Breast Cancer: Contribution of US as an Adjunct to MammographyRadiology, 1999