Comparison of IOP Measurements Between ORA and GAT in Normal Chinese
Authors:
- 1 September 2007
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 84 (9) , 909-914
Abstract
Purpose.: To compare intraocular pressure (IOP) obtained from the ocular response analyzer (ORA) and Goldmann applanation tonometer (GAT) on a group of normal Chinese. Methods.: One hundred twenty‐five normal subjects were recruited, with one eye randomly selected for this study. Each eye was measured first with the noncontact tonometer ORA, followed by the GAT and ultrasound pachometry, in a randomized order. Four readings were obtained from the ORA, and three measurements were taken with the GAT. The mean was used for analysis. The ORA provided a Goldmann‐correlated IOP (IOPg) and a corneal‐compensated IOP (IOPcc). Three central corneal thickness (CCT) values were measured using an ultrasound pachometer, and the mean was used for analysis. Results.: IOP obtained from the ORA was similar to that from the GAT (IOPg minus GAT: mean difference = 0.33 mm Hg, 95% limits of agreement = 4.55 to −4.44 mm Hg; IOPcc minus GAT: mean difference = 0.24 mm Hg, 95% limits of agreement = 4.83 to −5.07 mm Hg). CCT was positively associated with corneal hysteresis (CH) (r 2 = 0.30, p < 0.01), corneal resistance factor (r 2 = 0.38, p < 0.01), GAT (r 2 = 0.09, p < 0.01) and IOPg (r 2 = 0.16, p < 0.01). IOPcc was not associated with CCT (r 2 = 0.01, p = 0.33). Conclusions.: Both IOPg and IOPcc have good agreement with GAT on normal subjects. The influence of CCT on IOPcc was insignificant.Keywords
This publication has 26 references indexed in Scilit:
- Changes in Corneal Biomechanics and Intraocular Pressure Following LASIK Using Static, Dynamic, and Noncontact TonometryAmerican Journal of Ophthalmology, 2007
- The use of the Reichert ocular response analyser to establish the relationship between ocular hysteresis, corneal resistance factor and central corneal thickness in normal eyesContact Lens and Anterior Eye, 2006
- Corneal Thickness- and Age-Related Biomechanical Properties of the Cornea Measured with the Ocular Response AnalyzerInvestigative Ophthalmology & Visual Science, 2006
- Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma DamageAmerican Journal of Ophthalmology, 2006
- Evaluation of the Orssengo-Pye IOP corrective algorithm in LASIK patients with thick corneasOptometry - Journal of the American Optometric Association, 2005
- Determining in vivo biomechanical properties of the cornea with an ocular response analyzerJournal of Cataract & Refractive Surgery, 2005
- Influence of corneal biomechanical properties on intraocular pressure measurementJournal of Cataract & Refractive Surgery, 2005
- Intraocular pressure, Goldmann applanation tension, corneal thickness, and corneal curvature in Caucasians, Asians, Hispanics, and African AmericansAmerican Journal of Ophthalmology, 2003
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- Determination of the True Intraocular Pressure and Modulus of Elasticity of the Human Cornea in vivoBulletin of Mathematical Biology, 1999