The time variation of the F value (equilibrium factor) was estimated for one year in a typical Japanese apartment of reinforced concrete using the following equipment: a 300 ml flow-through scintillation flask for the hourly variation of radon concentration and a WL meter for the equilibrium equivalent concentration of radon (EEC Rn). These monitors operated for four to eight days at the end of each month, and the information obtained was assumed to be the representative value for each month. The annual mean of F = 0.43 ± 0.09 found for the dwelling agrees very well with the UNSCEAR value of 0.4 for indoors. In addition, it appears that the monthly F value in the dwelling varies over the range by a factor of 3. In addition the tendency of the seasonal variation in the other countries located at middle geographical latitudes is also observed in Japan. The variation of the F value in this case is mainly based on the changes in the life styles and activities of the inhabitants, especially the ventilation condition of the room due to opening/shutting of windows and air-conditioner operation. In seasons when windows were shut, the F value increased: when the windows were open or the air-conditioners were on, the F value decreased, especially when the EEC Rn decreased as a result of the filtration effect. If it is necessary to determine the radon effective dose over a shorter period than one year, the time variation of each physical or environmental parameter including F value should be taken into account.