Meta‐analysis of accuracy of intraocular lens power calculation formulas in short eyes
- 10 October 2017
- journal article
- research article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 46 (4) , 356-363
Abstract
Importance: Intraocular lens (IOL) power selection is a critical factor affecting visual outcome after IOL implantation in short eyes. Many formulas have been developed to achieve a precise prediction of the IOL power. However, controversy regarding the accuracy remains.Background: To investigate the accuracy of different IOL power calculation formulas in short eyes.Design: Meta‐analysis.Participants: Patients with the axial length of eyes less than 22 mm from previously reported studies.Methods: A comprehensive search in Pubmed, EMBASE, Cochrane Data Base of Systematic Reviews and the Cochrane Central Register of Controlled Trials was conducted by October 2016. We assessed the methodological quality using a modified QUADAS‐2 tool and performed analysis on weighted mean differences of mean absolute errors (MAE) among different formulas.Main Outcomes Measures: The between‐group difference of MAE was evaluated with weighted mean difference and 95% confidence intervals.Results: Ten observational studies, involving 1161 eyes, were enrolled to compare six formulas: Haigis, Holladay 2, Hoffer Q, Holladay 1, SRK/T and SRK II. Among them, the Holladay 2 introduced the smallest overall MAE (0.496D) without statistical significance. The difference of MAE is statistically significant between Haigis and Hoffer Q (mean difference = −0.07D, P = 0.003), Haigis and SRK/T (mean difference = −0.07D, P = 0.009), Haigis and SRK II (mean difference = −0.41D, P = 0.01). For publication bias and small‐study effect, neither funnel plot nor egger's test detected statistical finding.Conclusion and Relevance: The overall evidence from the studies confirmed the superiority of Haigis over Hoffer Q, SRK/T and SRK II in prediction IOL power in short eyes.Keywords
Funding Information
- National Natural Science Foundation of China (81700812, 81570889)
This publication has 32 references indexed in Scilit:
- Ultrasound Biometry vs. IOL MasterOphthalmology, 2012
- Accuracy of the Holladay 2 intraocular lens formula for pediatric eyes in the absence of preoperative refractionJournal of Cataract & Refractive Surgery, 2011
- Intraocular Lens Power Calculation Using IOLMaster and Various Formulas in Short EyesKorean Journal of Ophthalmology, 2011
- Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometryJournal of Cataract & Refractive Surgery, 2011
- Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopiaJournal of Cataract & Refractive Surgery, 2009
- Calculation of intraocular lens power: a reviewActa Ophthalmologica Scandinavica, 2007
- Präoperative Berechnung der Stärke intraokularer Linsen bei ProblemaugenZeitschrift für Medizinische Physik, 2007
- Biometry accuracy using zero- and negative-powered intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Refractive lensectomy for hyperopiaOphthalmology, 2000
- Refractive and visual outcome of hyperopic cataract cases operated on before and after implementation of the Holladay II formulaOphthalmology, 1998