Whole Body Center of Mass Estimation with Portable Sensors: Using the Statically Equivalent Serial Chain and a Kinect
Open Access
- 11 September 2014
- Vol. 14 (9) , 16955-16971
Abstract
The trajectory of the whole body center of mass (CoM) is useful as a reliable metric of postural stability. If the evaluation of a subject-specific CoM were available outside of the laboratory environment, it would improve the assessment of the effects of physical rehabilitation. This paper develops a method that enables tracking CoM position using low-cost sensors that can be moved around by a therapist or easily installed inside a patient’s home. Here, we compare the accuracy of a personalized CoM estimation using the statically equivalent serial chain (SESC) method and measurements obtained with the Kinect to the case of a SESC obtained with high-end equipment (Vicon). We also compare these estimates to literature-based ones for both sensors. The method was validated with seven able-bodied volunteers for whom the SESC was identified using 40 static postures. The literature-based estimation with Vicon measurements had a average error 24.9 ± 3.7 mm; this error was reduced to 12.8 ± 9.1 mm with the SESC identification. When using Kinect measurements, the literature-based estimate had an error of 118.4 ± 50.0 mm, while the SESC error was 26.6 ± 6.0 mm. The subject-specific SESC estimate using low-cost sensors has an equivalent performance as the literature-based one with high-end sensors. The SESC method can improve CoM estimation of elderly and neurologically impaired subjects by considering variations in their mass distribution.Keywords
This publication has 32 references indexed in Scilit:
- Identifiability and identification of inertial parameters using the underactuated base-link dynamics for legged multibody systemsThe International Journal of Robotics Research, 2013
- Exergaming for balance training of elderly: state of the art and future developmentsJournal of NeuroEngineering and Rehabilitation, 2013
- Concurrent neuromechanical and functional gains following upper-extremity power training post-strokeJournal of NeuroEngineering and Rehabilitation, 2013
- Familial or Sporadic Idiopathic Scoliosis – classification based on artificial neural network and GAPDH and ACTB transcription profileBioMedical Engineering OnLine, 2013
- Challenges, issues and trends in fall detection systemsBioMedical Engineering OnLine, 2013
- Accuracy and Resolution of Kinect Depth Data for Indoor Mapping ApplicationsSensors, 2012
- Introducing a feedback training system for guided home rehabilitationJournal of NeuroEngineering and Rehabilitation, 2010
- Improvement of diaphragm and limb muscle isotonic contractile performance by K+ channel blockadeJournal of NeuroEngineering and Rehabilitation, 2010
- Comparison of three methods to estimate the center of mass during balance assessmentJournal of Biomechanics, 2004
- Adjustments to Zatsiorsky-Seluyanov's segment inertia parametersJournal of Biomechanics, 1996