Multiphase non‐Newtonian effects on pulsatile hemodynamics in a coronary artery
Authors:
- 18 March 2008
- journal article
- research article
- Published by Wiley in International Journal for Numerical Methods in Fluids
- Vol. 58 (7) , 803-825
Abstract
Hemodynamic stresses are involved in the development and progression of vascular diseases. This study investigates the influence of mechanical factors on the hemodynamics of the curved coronary artery in an attempt to identify critical factors of non‐Newtonian models. Multiphase non‐Newtonian fluid simulations of pulsatile flow were performed and compared with the standard Newtonian fluid models. Different inlet hematocrit levels were used with the simulations to analyze the relationship that hematocrit levels have with red blood cell (RBC) viscosity, shear stress, velocity, and secondary flow. Our results demonstrated that high hematocrit levels induce secondary flow on the inside curvature of the vessel. In addition, RBC viscosity and wall shear stress (WSS) vary as a function of hematocrit level. Low WSS was found to be associated with areas of high hematocrit. These results describe how RBCs interact with the curvature of artery walls. It is concluded that although all models have a good approximation in blood behavior, the multiphase non‐Newtonian viscosity model is optimal to demonstrate effects of changes in hematocrit. They provide a better stimulation of realistic blood flow analysis. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 33 references indexed in Scilit:
- Multiphase hemodynamic simulation of pulsatile flow in a coronary arteryJournal of Biomechanics, 2006
- Computational Simulation of a Non‐Newtonian Model of the Blood Separation ProcessArtificial Organs, 2005
- Non-Newtonian blood flow in human right coronary arteries: steady state simulationsJournal of Biomechanics, 2004
- In Vitro Measurement of Fluid-Induced Wall Shear Stress in Unruptured Cerebral Aneurysms Harboring BlebsStroke, 2003
- Numerical Computation of the Steady Secondary Flow in a Tube with Time-Dependent CurvatureQuarterly Journal of Mechanics and Applied Mathematics, 2001
- Calculation of Unsteady Flows in Curved PipesJournal of Fluids Engineering, 2001
- The influence of the non-Newtonian properties of blood on the flow in large arteries: unsteady flow in a 90° curved tubeJournal of Biomechanics, 1999
- Fully developed intermittent flow in a curved tubeJournal of Fluid Mechanics, 1997
- MODELING OF CONCENTRATED LIQUID-SOLIDS FLOW IN PIPES DISPLAYING SHEAR-THINNING PHENOMENAChemical Engineering Communications, 1995