Flow diversion using the Pipeline embolization device for intracranial and extracranial pseudoaneurysms: a systematic review and meta-analysis of the literature
Authors:
Open Access
- 1 May 2023
- journal article
- review article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Neurosurgical Focus
- Vol. 54 (5) , E5
Abstract
OBJECTIVE: Pseudoaneurysms (PSAs) are complex vascular lesions. Flow diversion has been proposed as an alternative treatment to parent artery occlusion that preserves laminar flow. The authors of the present study investigated the safety and short-term (< 1 year) and long-term (≥ 1 year) aneurysm occlusion rates following the treatment of intracranial and extracranial PSAs using the Pipeline embolization device (PED). METHODS: An electronic database search for full-text English-language articles in Ovid MEDLINE and Epub Ahead of Print, Ovid Embase, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus was conducted following the PRISMA guidelines. Studies of any design including at least 4 patients with intracranial or extracranial PSAs treated using a PED were included in this analysis. The primary outcome of interest was the rate of peri- and postprocedural complications. Secondarily, the authors analyzed the incidence of complete aneurysm occlusion. RESULTS: A total of 90 patients with 96 PSAs across 9 studies were included. The mean age was 38.2 (SD 15.14) years, and 37.8% of the patients were women. The mean PSA size was 4.9 mm. Most PSAs were unruptured, and the most common etiology was trauma (n = 32, 35.5%), followed by spontaneous formation (n = 21, 23.3%) and iatrogenic injury (n = 19, 21.1%). Among the 51 (53.1%) intracranial and 45 (46.9%) extracranial PSAs were 19 (19.8%) dissecting PSAs. Sixty-six (77.6%) PSAs were in the internal carotid artery and 10 (11.8%) in the vertebral artery. Thirty-three (34.4%) PSAs were treated with ≥ 2 devices, and 8 (8.3%) underwent adjunctive coiling. The mean clinical and angiographic follow-up durations were 10.7 and 12.9 months, respectively. The short-term (< 1 year) and long-term (≥ 1 year) complete occlusion rates were 79% (95% CI 66%–88%, p = 0.82) and 84% (95% CI 70%–92%, p = 0.95), respectively. Complication rates were 8% for iatrogenic dissection (95% CI 3%–16%, p = 0.94), 10% for silent thromboembolism (95% CI 5%–21%, p = 0.77), and 12% for symptomatic thromboembolism (95% CI 6%–23%, p = 0.48). No treatment-related hemorrhage was observed. The overall mortality rate at the last follow-up was 14%. CONCLUSIONS: The complete occlusion rate for PSAs treated with the PED was high and increased over time. Although postprocedural complications and mortality were not insignificant, flow diversion represents a reasonably safe option for managing these complex lesions.Keywords
This publication has 22 references indexed in Scilit:
- Pipeline Embolization Device for Treatment of Extracranial Internal Carotid Artery Pseudoaneurysms: A Multicenter Evaluation of Safety and EfficacyNeurosurgery, 2020
- Efficacy of pipeline endovascular device and Willis stent graft in the treatment of traumatic pseudo intracranial aneurysmsJournal of Interventional Medicine, 2020
- Pipeline Embolization Device for the Treatment of Intracranial PseudoaneurysmsWorld Neurosurgery, 2019
- Probable pathogenesis, diagnosis, and management of untreated arteriovenous malformation with cyst formation: case report and literature reviewActa Neurologica Belgica, 2018
- Use of Pipeline™ embolization device for the treatment of traumatic intracranial pseudoaneurysms: Case series and review of cases from literatureClinical Neurology and Neurosurgery, 2018
- Flow-diverting Stent in the Treatment of Cervical Carotid Dissection and Pseudoaneurysm: Review of Literature and Case ReportAnnals of Vascular Surgery, 2018
- Flow diverter treatment of intracranial vertebral artery dissecting pseudoaneurysmsJournal of NeuroInterventional Surgery, 2017
- Vertebral artery pseudoaneurysms secondary to blunt trauma: Endovascular management by means of neurostents and flow divertersJournal of Clinical Neuroscience, 2016
- Pipeline Embolization Device for treatment of high cervical and skull base carotid artery dissections: clinical case seriesJournal of NeuroInterventional Surgery, 2015
- Primary endovascular treatment of post-irradiated carotid pseudoaneurysm at the skull base with the Pipeline embolization deviceJournal of NeuroInterventional Surgery, 2014