Analysis of PEM fuel cell – Supercapacitor – Battery pack system during standard cycle
Authors:
- 1 June 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1286-1290
Abstract
Today the application of PEM (Polymer Electrolyte Membrane) fuel cell stack in the automotive field is a topic on central interest. Unfortunately, a PEM fuel cell stack cannot directly supply variable speed drives because of their non-linear behaviour in dynamic conditions. This paper is mostly concerned with the sizing of the supply system, PEM fuel cell-supercapacitor-battery pack, of an electric vehicle, based on the urban/suburban drive cycle NEDC (New European Driving Cycle). The average required power is used to design the fuel cell stack by imposing a preset operating point; the battery capacity is chosen in order to satisfy the constrain on the minimum value of the state of charge during the cycle; finally, the supercapacitor is determined by imposing the current sharing between battery and supercapacitor in transient condition.Keywords
This publication has 6 references indexed in Scilit:
- Minimum supercapacitor choice to provide current step variation in FC PEM2007
- An Experimental Approach to the Modeling of PEM Fuel Cells in Dynamic Conditions2007
- Supercapacitor to provide current step variation in FC PEM2007
- An automatic test system for the dynamic characterization of PEM fuel cells2004
- Fuel cellsPower Engineering Journal, 2002
- Fuel cell systems: efficient, flexible energy conversion for the 21st centuryProceedings of the IEEE, 2001