Kinematics and stability of the Norway elbow: A cadaveric study
Authors:
- 1 January 1993
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 64 (6) , 657-663
Abstract
We investigated the effect of simulated muscle loading and the contribution of the radial head to stability of the Norway elbow in 6 cadavers using an electromagnetic tracking device. The kinematics of the elbow after implantation of the prosthesis were similar to the intact elbow in their valgus-varus orientation, however, the forearms were slightly externally rotated, probably due to a small amount of external rotation of the humeral components at the time of implantation. The valgus-varus laxity limit of the implants were greater than in the intact specimens averaging 8.0 and 5.6 degrees, respectively. Simulated muscle loading stabilized both the intact and the Norway elbows. Excision of the radial head after implant arthroplasty increased their valgus-varus laxity, suggesting that preservation of the radial head may be indicated if it is not too severely involved by the underlying disease process. The laxity permitted by the prosthesis articulation is greater than that measured after implantation of the Norway arthroplasty. This suggests that the prosthesis may behave as an unconstrained arthroplasty. This should minimize the stress experienced by the bone-cement interface and may reduce the incidence of loosening. The laxity of the elbows after joint arthroplasty were only slightly greater than normal, possibly explaining the low incidence of prosthesis dislocation which has been observed with clinical use.Keywords
This publication has 16 references indexed in Scilit:
- In vitro stability of an unconstrained total elbow prosthesisThe Journal of Arthroplasty, 1993
- Kinematics of semi-constrained total elbow arthroplastyThe Journal of Bone and Joint Surgery. British volume, 1992
- Valgus Stability of the ElbowClinical Orthopaedics and Related Research, 1991
- Capitello-condylar total elbow arthroplasty for rheumatoid arthritisThe Journal of Arthroplasty, 1990
- Nonconstrained total elbow arthroplastyThe Journal of Arthroplasty, 1989
- Ligament length relationships in the moving kneeJournal of Orthopaedic Research, 1988
- Capitellocondylar Total Elbow ArthroplastyClinical Orthopaedics and Related Research, 1987
- Valgus stability of the elbowJournal of Orthopaedic Research, 1987
- The development of an unconstrained elbow arthroplasty. A clinical reviewThe Journal of Bone and Joint Surgery. British volume, 1984
- Muscles across the elbow joint: A biomechanical analysisJournal of Biomechanics, 1981