Climbing robot for corrosion monitoring of reinforced concrete structures
- 1 September 2012
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 10-15
Abstract
This paper introduces a climbing robot for corrosion monitoring of reinforced concrete structures such as cooling towers, dams or bridges. The robot combines a vortex adhesion mechanism with a wheel electrode sensor for potential mapping of the concrete surface. A detailed description of the system is presented first. A special effort was made during the design in order to develop a lightweight device. The climbing robot is well suited for rough surfaces and can climb on vertical surfaces or move upside-down. The experiments that have been done to validate the concept are presented afterwards. They show that the climbing robot has several advantages over the traditional corrosion monitoring technique. This robot will therefore provide engineers in charge of infrastructure maintenance with the means to do their job much better than they can today. It offers them a way to circumvent all present barriers and brings a radical innovation in this area.Keywords
This publication has 8 references indexed in Scilit:
- Concrete cover cracking owing to reinforcement corrosion – theoretical considerations and practical experienceMaterials and Corrosion, 2012
- PARASWIFT – A HYBRID CLIMBING AND BASE JUMPING ROBOT FOR ENTERTAINMENT2011
- Advanced Robot System for Automated Bridge Inspection and Monitoring2009
- STRUCTURE AND MODEL IDENTIFICATION OF A VORTEX-BASED SUCTION CUP2008
- City-Climber: A New Generation Wall-Climbing Robots2007
- Half-cell potential measurements—Potential mapping on reinforced concrete structuresMaterials and Structures, 2003
- A Climbing Robot for the Assessment of Civil Infrastructures2002
- Half-cell potential mapping to assess repair work on RC structuresConstruction and Building Materials, 2001