Nanomechanical clinical coagulation diagnostics and monitoring of therapies
- 24 October 2017
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 9 (45) , 17939-17947
Abstract
Clinical coagulation diagnostics often requires multiple tests. Coagulation times are a first indication of an abnormal coagulation process, such as a coagulation factor deficiency. To determine the specific deficient factor, additional immuno- and/or enzyme assays are necessary. Currently, every clinical laboratory has to normalize their assays (international normalized ratio, INR), and therefore, certain variability within the clinical analytics exists. We report a novel strategy for a quick, reliable and quantitative diagnosis of blood coagulation diseases (e.g. haemophilia) and for monitoring factor replacement and anticoagulant therapies (e.g. heparin treatment). We exploit nano-oscillations of microcantilevers for real-time measurements of the evolving blood plasma clot strength (viscosity). The sensors are oscillated at multiple high resonance mode numbers, in order to minimise the oscillation amplitude (a few nanometers), to provide direct internal control and to increase the quality factor. Along with the activated thromboplastin time (aPTT) and prothrombin time (PT) other parameters important for thrombosis diagnostics can be obtained, including the final clot strength and the fibrinolysis time. We demonstrate the dependence of the parameters on factor deficiencies and we diagnose a specific factor deficiency through an integrated and quantitative in situ immunoassay. This approach does not require continuous calibration since it delivers an absolute quantity (clot strength). The low sample volume required (a few μl) and the ability to measure different parameters within the same test (PT, aPTT and global coagulation assay) make the presented technique a versatile point-of-care device for clinical coagulation diagnostics.Keywords
Funding Information
- Science Foundation Ireland (SFI/09IN/1B2623, SFI/10/CSET/B1821, SFI/15/IA/3023)
This publication has 42 references indexed in Scilit:
- Thrombelastography (TEG®): practical considerations on its clinical use in trauma resuscitationScandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 2013
- TEG® and ROTEM® in trauma: similar test but different results?World Journal of Emergency Surgery, 2012
- Protein thin film machinesNanoscale, 2010
- Primary Fibrinolysis Is Integral in the Pathogenesis of the Acute Coagulopathy of TraumaAnnals of Surgery, 2010
- Tissue plasminogen activator induced fibrinolysis: standardization of method using thromboelastographyBlood Coagulation & Fibrinolysis, 2010
- Factor XIII deficiencyHaemophilia, 2008
- Micromechanical mass sensors for biomolecular detection in a physiological environmentPhysical Review E, 2005
- Interpretation of Protein Adsorption: Surface-Induced Conformational ChangesJournal of the American Chemical Society, 2005
- Blood plasma coagulation studied by surface plasmon resonanceJournal of Biomedical Optics, 2000
- Blutgerinnungsstudien mit der Thrombelastographie, einem neuen UntersuchungsverfahrenJournal of Molecular Medicine, 1948