Dynamic cascade-model-based frequency-scanning interferometry for real-time and rapid absolute optical ranging
Authors:
- Zhongwen DengZDZhongwen Deng
- Zhigang LiuZLZhigang Liu
- Xingyu JiaXJXingyu Jia
- Wen DengWDWen Deng
- Xin ZhangXZXin Zhang
- 19 July 2019
- journal article
- research article
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (15) , 21929-21945
Abstract
A new frequency-scanning interferometry (FSI) scheme using in-phase and quadrature (IQ) detection for real-time and rapid absolute optical ranging is presented. Dynamic measurement with FSI modulates interference signal frequency by both target movement and time-varying optical-frequency scanning rate; hence, a dynamic model is proposed to decouple dynamic absolute distance from the instantaneous frequency of interference signals. The unscented Kalman filter and particle filter algorithms are implemented for the nonlinear first-layer and non-Gaussian second-layer models, respectively. The proposed FSI scheme eliminates nonlinear optical-frequency scanning effects in dynamic measurements and realizes real-time measurement only current observed data are used. Experimental results verify high tracking performance for a vibrating target with approximately 10 μm amplitude and 50-500 Hz frequency.Keywords
Funding Information
- National Natural Science Foundation of China (NSFC) (51635010, 51875447)
This publication has 29 references indexed in Scilit:
- Precision improvement in frequency-scanning interferometry based on suppressing nonlinear optical frequency sweepingOptical Review, 2015
- Dual-Sweep Frequency Scanning Interferometry Using Four Wave MixingIEEE Photonics Technology Letters, 2015
- Frequency-scanning interferometry for dynamic absolute distance measurement using Kalman filterOptics Letters, 2014
- Comb-calibrated laser ranging for three-dimensional surface profiling with micrometer-level precision at a distanceOptics Express, 2014
- High-resolution frequency-modulated continuous-wave laser ranging for precision distance metrology applicationsOptical Engineering, 2014
- In vivo Fourier-domain full-field OCT of the human retina with 15 million A-lines/sOptics Letters, 2010
- Resolution improvement in vertical-cavity-surface-emitting-laser diode interferometry based on linear least-squares estimation of phase gradients of phase-locked fringesOptical Review, 2010
- Dual-frequency sweeping interferometry for absolute metrology of long distancesOptical Engineering, 2010
- The unscented Kalman filter for nonlinear estimation2002
- Distance measurement of moving objects by frequency modulated laser radarOptical Engineering, 2001