Abstract
Objectives: The aim of the present study was to determine the outcomes of using the Valeo stent (Bard Peripheral Vascular, Tempe, Arizona, United States of America) in small children with CHD.Background: Stenting vascular stenoses is safe and effective in adults and older children with CHD but is limited in smaller children. The design of the Valeo stent addresses these limitations but has not been extensively described.Methods: Bench testing was conducted to determine the maximum diameter of the stent, foreshortening, and side-cell diameter. A retrospective analysis of Valeo stents implanted between October, 2012 and October, 2014 was performed. Patient profile, pre-implant/post-implant catheterization data, and stent geometry were reviewed.Results: Bench testing: medium and large Valeo stents can be dilated up to 13 mm and 20 mm diameters, respectively. Side-cells are dilatable up to 12 mm. Valeo stents are of low profile – delivered through 6- or 7-Fr sheaths – and show minimal foreshortening. Retrospective analysis: a total of 81 stents were implanted in 61 patients with CHD. The median weight was 15.3 kg, and the median age was 58.9 months. Stents were implanted in the pulmonary artery, systemic vein, aorta, and pulmonary vein. Overall, mean vessel diameters increased from 4.1 to 7.7 mm (121.7%). There was effective mean gradient reduction: 3.7–0.5 mmHg (63%) in the venous systems, 28.2–12.5 mmHg (63.7%) in the pulmonary arteries, and 17.4–4 mmHg (77.1%) in the aorta. The mean stent foreshortening was 2.5%, and the mean recoil was 5.9%. Side-cells that crossed other vessels were dilated in four cases, and stents were re-mounted onto different-sized balloons in seven cases.Conclusions: The features of the Valeo stent, such as low profile, large maximum diameter, open-cell design, minimal foreshortening, and recoil, make it suitable for treating vascular stenoses in small children with CHD.Keywords
This publication has 8 references indexed in Scilit:
- Implantation and preliminary follow‐up of the Bard Valeo stent in pulmonary artery stenosisCatheterization and Cardiovascular Interventions, 2014
- The role of the new Valeo stent for treating pulmonary artery stenoses in children with complex cardiac malformationsAmerican Journal of Case Reports, 2014
- Using the Valeo dilatable stent in coarctation stenting for small children: expanding the inclusion criteria for coarctation stenting?BMJ Case Reports, 2013
- Extensive distortion and dysfunction of an Edwards Valeo lifestent placed for stenosis of the superior vena cavaCatheterization and Cardiovascular Interventions, 2011
- A premounted stent that can be implanted in infants and re‐dilated to 20 mm: Introducing the Edwards Valeo LifestentCatheterization and Cardiovascular Interventions, 2009
- The role of stents in the treatment of congenital heart disease: Current status and future perspectivesAnnals of Pediatric Cardiology, 2009
- Stents: What's available to the pediatric interventional cardiologist?Catheterization and Cardiovascular Interventions, 2002
- Implantation of balloon-expandable intravascular grafts by catheterization in pulmonary arteries and systemic veins.Circulation, 1988