The effect of radial head fracture size on elbow kinematics and stability
Authors:
- Cynthia E. DunningCDCynthia E. Dunning
- Karen D. GordonKGKaren D. Gordon
- James A. JohnsonJJJames A. Johnson
- Graham J. W. KingGKGraham J. W. King
- 1 January 2005
- journal article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 23 (1) , 210-217
Abstract
This study determined the effect of radial head fracture size and ligament injury on elbow kinematics. Eight cadaveric upper extremities were studied in an in vitro elbow simulator. Testing was performed with ligaments intact, with the medial collateral (MCL) or lateral collateral (LCL) ligament detached, and with both the MCL and LCL detached. Thirty degree wedges were sequentially removed from the anterolateral radial head up to 120°. Valgus angulation and external rotation of the ulna relative to the humerus were determined for passive motion, active motion, and pivot shift testing with the arm in a vertical (dependent) orientation. Maximum varus–valgus laxity was calculated from measurements of varus and valgus angulation with the arm in horizontal gravity‐loaded positions. No effect of increasing radial head fracture size was observed on valgus angulation during passive and active motion in the dependent position. In supination, external rotation increased with increasing fracture size during passive motion with LCL deficiency and both MCL and LCL deficiency. With intact ligaments, maximum varus–valgus laxity increased with increasing radial head fracture size. With ligament disruption, elbows were grossly unstable, and no effect of increasing radial head fracture size occurred. During pivot shift testing, performed with the ligaments intact, subtle instability was noted after resection of one‐third of the radial head. In this in vitro biomechanical study, small subtle effects of radial head fracture size on elbow kinematics and stability were seen in both the ligament intact and ligament deficient elbows. These data suggest that fixation of displaced radial head fractures less than or equal to one‐third of the articular diameter may have some biomechanical advantages; however, clinical correlation is required. © 2004 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.Keywords
This publication has 15 references indexed in Scilit:
- The effect of radial head fracture size on radiocapitellar joint stabilityClinical Biomechanics, 2003
- Simulated active control produces repeatable motion pathways of the elbow in an in vitro testing systemJournal of Biomechanics, 2001
- Muscle Forces and Pronation Stabilize the Lateral Ligament Deficient ElbowClinical Orthopaedics and Related Research, 2001
- Rehabilitation of the medial collateral ligament-deficient elbow: An in vitro biomechanical studyThe Journal of Hand Surgery, 2000
- Displaced Fractures of the Radial Head: Internal Fixation or Excision?Journal of the American Academy of Orthopaedic Surgeons, 1997
- Accuracy of an electromagnetic tracking device: A study of the optimal operating range and metal interferenceJournal of Biomechanics, 1996
- Radial Head FractureClinical Orthopaedics and Related Research, 1993
- Open Reduction and Internal Fixation of Radial Head FracturesJournal of Orthopaedic Trauma, 1991
- Internal Fixation of Proximal Radial Head FracturesJournal of Orthopaedic Trauma, 1990