Analytical Modeling and Numerical Simulation of Forces in an Endoluminal Graft
- 1 August 2001
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 8 (4) , 358-371
Abstract
Purpose: To utilize mathematical analysis and computational fluid dynamics (CFD) to investigate the forces acting within the pressurized aorta and upon a stent-graft and how these forces may affect the ongoing performance of the stent-graft. Methods: Analytical force balance analysis and CFD simulations using the Fluent code were used to mimic blood flow through a bifurcated stent-graft in a person at rest. Steadystate blood flow was assumed in which the inlet pressure approximated the mean blood pressure (100 mm Hg) and the blood flow velocity was an approximation of the peak systolic flow rate (0.6 m/s). Two sizes of endoluminal grafts were analyzed: the larger graft had an inlet diameter of 3 cm and outlet diameters of 1 cm; the smaller graft diameters measured 2.4 cm proximally and 1.2 cm distally. The endografts were studied in 2 configurations: with the limbs straight and with one bent. Results: For the larger graft model, the normal peak blood flow induced a downward force of 7 to 9 N on the bifurcated grafts. Bending one of the limbs of the graft produced a sideways force of 1.3 N. For the smaller endograft, the downward force was in the range of 3.1 to 5.1 N and the sideways force on a curved limb was ∼1.5 N. The magnitude of the forces given by the analytical formulae and the CFD results agreed to within 2 significant figures. Conclusions: These results suggest that the downward force on a bifurcated stent-graft, which may exceed the force required to dislodge it when relying on radial attachment alone, is determined mostly by the proximal graft diameter. Curvature of the graft limbs creates an additional sideways force that works to displace the distal limbs of the graft from the iliac arteries.Keywords
This publication has 9 references indexed in Scilit:
- Time-Related Alterations in Shape, Position, and Structure of Self-Expanding, Modular Aortic Stent-Grafts: A 4-year Single-Center Follow-upJournal of Endovascular Therapy, 1999
- Three-Year Experience with the White-Yu Endovascular GAD Graft for Transluminal Repair of Aortic and Iliac AneurysmsJournal of Endovascular Therapy, 1997
- The Need for Clinical Trials of Endovascular Abdominal Aortic Aneurysm Stent-Graft Repair: The EUROSTAR ProjectJournal of Endovascular Therapy, 1997
- BLOOD FLOW IN ARTERIESAnnual Review of Fluid Mechanics, 1997
- The Perth Endoluminal Bifurcated Graft System — Development and Early ExperienceCardiovascular Surgery, 1996
- Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repairJournal of Vascular Surgery, 1996
- Early Experience with the Sydney and EVT Prostheses for Endoluminal Treatment of Abdominal Aortic AneurysmsJournal of Endovascular Therapy, 1995
- Turbulence in the canine ascending aorta and the blood pressureBiorheology, 1991
- The numerical computation of turbulent flowsComputer Methods in Applied Mechanics and Engineering, 1974