Abstract
Hip fractures secondary to osteoporosis are common in the elderly. Stabilizing these fractures until union is achieved is a challenge due to poor bone stock and insufficient purchase of the implant to the bone. The reported high rate of complications has prompted extensive research in the development of fixation techniques. Furthermore, manipulation of both the local fracture environment in terms of application of growth factors, scaffolds, and mesenchymal cells and the systemic administration of agents promoting bone formation and bone strength has been considered as a treatment option with promising results. There are only a few evidence-based studies reporting on fixation augmentation techniques. This article reports on the efficacy of bone graft substitutes for the fixation of hip fractures, in particular calcium phosphates, which have been used as granules, cements, and implant coatings.Keywords
This publication has 31 references indexed in Scilit:
- Principles of fixation of osteoporotic fracturesThe Journal of Bone and Joint Surgery. British volume, 2006
- Resorbable cement for the augmentation of internally-fixed unstable trochanteric fracturesThe Journal of Bone and Joint Surgery. British volume, 2005
- Hydroxyapatite-coated external-fixation pinsThe Journal of Bone and Joint Surgery. British volume, 2004
- Dynamic Hip Screw With Trochanteric Stabilizing Plate in the Treatment of Unstable Proximal Femoral Fractures: A Comparative Study With the Gamma Nail and Compression Hip ScrewJournal of Orthopaedic Trauma, 1998
- Norian SRS Cement Augmentation in Hip Fracture TreatmentClinical Orthopaedics and Related Research, 1998
- Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hipThe Journal of Bone and Joint Surgery. British volume, 1997
- Hydroxyapatite Coated External Fixation PinsClinical Orthopaedics and Related Research, 1996
- Sliding hip screws: modes of failureInjury, 1989
- Glycosaminoglycan Metabolism in Experimental Osteoarthrosis Caused by ImmobilizationActa Orthopaedica, 1978
- Unstable Trochanteric Fractures Treated with the Sliding Screw-Plate System:A Biomechanical Study of Unstable Trochanteric FracturesIIIActa Orthopaedica, 1978