Detection of crystal lattice defects in microranges of copper by X-ray interferences
Authors:
- Siegfried DäbritzSDSiegfried Däbritz
- Herwig HornHHHerwig Horn
- Hanns WaltingerHWHanns Waltinger
- 1 January 1999
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 14 (3) , 487-492
Abstract
The lattice source interferences (LSI) or Kossel technique and the divergent beam X-ray interferences (DBI) or pseudo-Kossel technique are highly sensitive to the real structure in the microrange of the crystal lattice. Both methods complement each other, owing to their geometrically different diffraction regions. Mechanically ground and polished Cu single crystals with different crystallographic orientations ([100], [110], [621], [694]) and two polycrystalline Cu specimens were chemically etched stepwise with FeCl 3 ·6H 2 O. After each etching time, divergent beam X-ray patterns of the crystals were taken and in some cases lattice source interferences pattern also. It was possible to observe the real structure as a function of the depth, because the information comes from a depth of about 2-5 µm for LSI and 50-100 µm for DBI. The DBI patterns show, for instance, for Cu [100], sharp interference lines from regions up to 40 µm deep. With increasing depth the crystal lattice reveals the real structure only and not the deformation effect caused by polishing.Keywords
This publication has 9 references indexed in Scilit:
- Combined use of lattice source interferences and divergent beam X-ray interferences to investigate the microstructure of ion-bombarded Cu-Sn-diffusion zonesAnalytical and Bioanalytical Chemistry, 1997
- Investigation of the Crystalline State of Identical Sample Domains by Means of Divergent X‐ray Beam Technique in the Direction of Transmission and Reflection in the Scanning Electron Microscope (SEM)Crystal Research and Technology, 1986
- Orientation Dependence of the Effective Depth of X-Ray penetrationPhysica Status Solidi (a), 1986
- A new diffraction method for the determination of the effective depth of X-Ray penetrationPhysica Status Solidi (a), 1986
- Bestimmung der Versetzungsdichte im SinterkontaktbereichMicrochimica Acta, 1983
- Kossel Line Broadening near a Scratch on GaPPhysica Status Solidi (a), 1982
- Kossel line profiles near dislocations in GaPPhysica Status Solidi (a), 1981
- Strain and Precision Lattice Parameter Measurements by the X-Ray Divergent Beam Method. IJournal of Applied Physics, 1964
- A study of age-hardening of Al–3.85% Cu by the divergent X-ray beam methodActa Crystallographica, 1962