Considerations on Revisions of Emissions Testing Protocols
Authors:
- 1 January 1996
- book chapter
- Published by ASTM International
- p. 225-236
Abstract
The ASTM Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products (ASTM D 5116) was first published in 1990 and is due for review and revision in 1995. Since its publication, we have gained a substantial amount of information about emissions processes that may affect the implementation of the test method. The upcoming revision will be an opportunity to incorporate that information. This paper addresses several issues that should be considered in the revision. The effect of air velocity on emissions was demonstrated by testing a constant evaporative source. When the air velocity increased from <3 to 46 cm/s, the emission rate increased by a factor of three. Given the importance of this parameter, its measurement should be standardized. A wood finishing product was applied to the substrate with different sizes and tested in small chambers. When the size of the test specimen was reduced from 221 to 12 cm2, the mass transfer coefficient increased by a factor of three, suggesting that the “edge effect” can be an important factor affecting the rate of emissions from test specimens. ASTM D 5116 should enhance its discussions on emission factor estimation to include a wider range of models and different methods by which the model parameters are determined. Computer simulations showed that, when indoor coating materials are tested in chambers, loss of volatile components from the source during sample preparation can cause errors in emission factor estimates.Keywords
This publication has 13 references indexed in Scilit:
- Modeling emissions of volatile organic compounds from new carpetsAtmospheric Environment, 1994
- Fundamental Mass Transfer Model for Indoor Air Emissions from Surface CoatingsIndoor Air, 1993
- On Validation of Source and Sink Models: Problems and Possible Solutions1993
- Emission of Volatile Organic Compounds from a Vinyl Floor Covering1993
- Evaluation of Para-Dichlorobenzene Emissions from Solid Moth Repellant as a Source of Indoor Air PollutionJournal of the Air & Waste Management Association, 1992
- Comparison of Models used to Estimate Parameters of Organic Emissions from Materials Tested in Small Environmental ChambersIndoor Air, 1992
- The effect of ventilation on emission rates of wood finishing materialsEnvironment International, 1991
- Compensating for sink effects in emissions test chambers by mathematical modelingAtmospheric Environment (1967), 1988
- Interlaborafory Comparison of Formaldehyde Emissions from Particleboard Underlayment in Small-Scale Environmental ChambersJAPCA, 1987
- A Model for Formaldehyde Release from Particleboard1986