The Application of Magnetic Shielding Effect in Drill Pipe Magnetic Leakage Flux Testing
Authors:
- Ma YilaiMYMa Yilai
- Lin LiLLLin Li
- Jiang KaiwenJKJiang Kaiwen
- Zhao XulinZXZhao Xulin
- 1 January 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 44 47 (21571473) , 1135-1138
Abstract
Electromagnetic finite element analysis shows that pipe magnetic flux leakage signals are centralized near defects obviously when the magnetic shielding exists. At this time, the background magnetic flux between permanent magnet components coupling through the air medium will be reduced greatly. Drill pipe magnetic flux leakage testing confirms the analysis results, and the probe with magnetic shielding device can improve SNR of the magnetic flux leakage signals obviously. Thus, it is helpful to improve pipe leakage flux testing sensitivity.Keywords
This publication has 4 references indexed in Scilit:
- Effects of Apparatus Parameters on MFL Signals Using Orthogonal Experimental DesignApplied Mechanics and Materials, 2010
- Data Fusion for MFL Signal CharacterizationApplied Mechanics and Materials, 2010
- Experiment and simulation study of 3D magnetic field sensing for magnetic flux leakage defect characterisationNDT & E International, 2007
- FEM modelling techniques of magnetic flux leakage-type NDT for ferromagnetic plate inspectionsJournal of Magnetism and Magnetic Materials, 2006