Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts
Open Access
- 1 January 2007
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 6 (1) , 35
Abstract
Coronary artery bypass graft (CABG) surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS), in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD). One patient with saphenous CABG and end-to-side anastomosis and one patient with saphenous CABG and side-to-side anastomosis underwent 16-detector row computed tomography (CT). Geometric models of coronary arteries and bypasses were reconstructed for CFD analysis. Blood flow was considered pulsatile, laminar, incompressible and Newtonian. Peri-anastomotic mass flow and WSS were quantified and flow patterns visualized. CFD analysis based on in-vivo CT coronary angiography data was feasible in both patients. For both types of CABG, flow patterns were characterized by a retrograde flow into the native coronary artery. WSS variations were found in both anastomoses types, with highest WSS values at the heel and lowest WSS values at the floor of the end-to-side anastomosis. In contrast, the highest WSS values of the side-to-side anastomosis configuration were found in stenotic vessel segments and not in the close vicinity of the anastomosis. Flow stagnation zones were found in end-to-side but not in side-to-side anastomosis, the latter also demonstrating a smoother stream division throughout the cardiac cycle. CFD analysis of venous CABG based on in-vivo CT datasets in patients was feasible producing qualitative and quantitative information on mass flow and WSS. Differences were found between the two types of anastomosis warranting further systematic application of the presented methodology on multiple patient datasets.Keywords
This publication has 53 references indexed in Scilit:
- Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate controlEuropean Radiology, 2006
- Analysis of blood flow in an out-of-plane CABG modelAmerican Journal of Physiology-Heart and Circulatory Physiology, 2006
- Computational simulation of intracoronary flow based on real coronary geometry☆European Journal of Cardio-Thoracic Surgery, 2004
- Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasiaJournal of Biomechanics, 1996
- The Effect of Angle and Flow Rate Upon Hemodynamics in Distal Vascular Graft Anastomoses: A Numerical Model StudyJournal of Biomechanical Engineering, 1994
- Spatial and temporal variations of wall shear stress within an end-to-side arterial anastomosis modelJournal of Biomechanics, 1993
- The Role of Fluid Mechanics in the Localization and Detection of AtherosclerosisJournal of Biomechanical Engineering, 1993
- A Numerical Simulation of Flow in a Two-Dimensional End-to-Side Anastomosis ModelJournal of Biomechanical Engineering, 1993
- Vascular Fluid Mechanics, the Arterial Wall, and AtherosclerosisJournal of Biomechanical Engineering, 1992
- Saphenous Vein Autograft Replacement of Severe Segmental Coronary Artery OcclusionThe Annals of Thoracic Surgery, 1968