A control algorithm of power converters in smart-grids for providing uninterruptible ancillary services
- 1 September 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15406008,p. 1-7
Abstract
This paper deals with the use of grid-connected photovoltaic (PV) power plants for supplying the ancillary service of reactive power compensation to the distribution grid. A control strategy has been developed for controlling both real and reactive power exchanged with the distribution network. The paper suggests how the real and reactive power references should be selected in order to maximize the electrical energy generated by PV arrays and to exploit the apparent power of the inverter close to its rated value. The choice suggested for reference signals allows reactive power compensation service also when the solar irradiation is negligible. The control strategy is then applied to a sample grid-connected PV unit, which has been simulated in Simulink environment. Numerical simulations show that, using an adaptive Perturb & Observe algorithm, the maximum power point tracking is achieved in about 2 seconds, both at starting and when the irradiation changes. The inverter is also capable of giving without interruptions the reactive power support to the grid, reducing grid currents and voltage drops along the line respect to the classical configuration where no reactive compensation is present.Keywords
This publication has 11 references indexed in Scilit:
- Adaptive perturb and observe algorithm for photovoltaic maximum power point trackingIET Renewable Power Generation, 2010
- Design and Analysis of a Grid-Connected Photovoltaic Power SystemIEEE Transactions on Power Electronics, 2009
- Photovoltaic Generating Units as Reactive Supply Ancillary Service ProvidersInternational Journal of Emerging Electric Power Systems, 2008
- A Single-Phase Voltage-Controlled Grid-Connected Photovoltaic System With Power Quality Conditioner FunctionalityIEEE Transactions on Industrial Electronics, 2008
- An active filter used for harmonic compensation and power factor correction: A control technique2008
- Performance Analysis of Active Filters Used for Harmonic Compensation2006
- Design and Control of an LCL-Filter-Based Three-Phase Active RectifierIEEE Transactions on Industry Applications, 2005
- Analysis of active filter behaviour by means of modified 𝒵-transform methodIEE Proceedings - Electric Power Applications, 2005
- Approaches to analytical analysis of active filter behaviour2003
- Wide bandwidth single and three-phase PLL structures for grid-tied PV systems2002