Data Mining of the Thermal Performance of Cool‐Pipes in Massive Concrete via In Situ Monitoring
Open Access
- 1 January 2014
- journal article
- research article
- Published by Wiley in Mathematical Problems in Engineering
- Vol. 2014 (1)
Abstract
Embedded cool‐pipes are very important for massive concrete because their cooling effect can effectively avoid thermal cracks. In this study, a data mining approach to analyzing the thermal performance of cool‐pipes via in situ monitoring is proposed. Delicate monitoring program is applied in a high arch dam project that provides a good and mass data source. The factors and relations related to the thermal performance of cool‐pipes are obtained in a built theory thermal model. The supporting vector machine (SVM) technology is applied to mine the data. The thermal performances of iron pipes and high‐density polyethylene (HDPE) pipes are compared. The data mining result shows that iron pipe has a better heat removal performance when flow rate is lower than 50 L/min. It has revealed that a turning flow rate exists for iron pipe which is 80 L/min. The prediction and classification results obtained from the data mining model agree well with the monitored data, which illustrates the validness of the approach.Keywords
Funding Information
- Ministry of Education of the People’s Republic of China (2013CB035902, 2012-KY-4, 51279087, 51339003)
- Research Project of State Key Laboratory of Hydroscience and Engineering of Tsinghua University (2013CB035902, 2012-KY-4, 51279087, 51339003)
- National Natural Science Foundation of China (2013CB035902, 2012-KY-4, 51279087, 51339003)
- National Natural Science Foundation of China (2013CB035902, 2012-KY-4, 51279087, 51339003)
This publication has 28 references indexed in Scilit:
- Boolean-Based Surface Procedure for the External Heat Transfer Analysis of Dams during ConstructionMathematical Problems in Engineering, 2013
- Thermal Load in Large-Scale Bridges: A State-of-the-Art ReviewInternational Journal of Distributed Sensor Networks, 2013
- Health Condition Evaluation of Cable-Stayed Bridge Driven by Dissimilarity Measures of Grouped Cable ForcesInternational Journal of Distributed Sensor Networks, 2013
- Behavior of HPC with Fly Ash after Elevated TemperatureAdvances in Materials Science and Engineering, 2013
- Thermal analysis of mass concrete embedded with double-layer staggered heterogeneous cooling water pipesApplied Thermal Engineering, 2012
- Top 10 algorithms in data miningKnowledge and Information Systems, 2007
- Influence of the different pipe cooling scheme on temperature distribution in RCC arch damsCommunications in Numerical Methods in Engineering, 2005
- What Is a “Massive” Concrete Structure at Early Ages? Some Dimensional ArgumentsJournal of Engineering Mechanics, 2001
- Effect of Cooling by Water Flowing in Nonmetal Pipes Embedded in Mass ConcreteJournal of Construction Engineering and Management, 1999
- Finite Element Analysis of Effect of Pipe Cooling in Concrete DamsJournal of Construction Engineering and Management, 1989