Long-term recording reliability of liquid crystal polymer µ ECoG arrays
- 22 October 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 15 (6) , 066024
Abstract
Objective . The clinical use of microsignals recorded over broad cortical regions is largely limited by the chronic reliability of the implanted interfaces. Approach . We evaluated the chronic reliability of novel 61-channel micro-electrocorticographic ( µ ECoG) arrays in rats chronically implanted for over one year and using accelerated aging. Devices were encapsulated with polyimide (PI) or liquid crystal polymer (LCP), and fabricated using commercial manufacturing processes. In vitro failure modes and predicted lifetimes were determined from accelerated soak testing. Successful designs were implanted epidurally over the rodent auditory cortex. Trends in baseline signal level, evoked responses and decoding performance were reported for over one year of implantation. Main results . Devices fabricated with LCP consistently had longer in vitro lifetimes than PI encapsulation. Our accelerated aging results predicted device integrity beyond 3.4 years. Five implanted arrays showed stable performance over the entire implantation period (247–435 d). Our regression analysis showed that impedance predicted signal quality and information content only in the first 31 d of recordings and had little predictive value in the chronic phase (>31 d). In the chronic phase, site impedances slightly decreased yet decoding performance became statistically uncorrelated with impedance. We also employed an improved statistical model of spatial variation to measure sensitivity to locally varying fields, which is typically concealed in standard signal power calculations. Significance . These findings show that µ ECoG arrays can reliably perform in chronic applications in vivo for over one year, which facilitates the development of a high-density, clinically viable interface.Keywords
Funding Information
- Steven W Smith Fellowship
- Defense Advanced Research Projects Agency (DARPA-BAA-16-09)
- Division of Computing and Communication Foundations (CCF1422914, CCF-1564051)
- National Institute of Neurological Disorders and Stroke (U01 NS099697)
- Howard Hughes Medical Institute
- National Institute on Deafness and Other Communication Disorders (DC015543)
This publication has 106 references indexed in Scilit:
- Theoretical analysis of intracortical microelectrode recordingsJournal of Neural Engineering, 2011
- Long-term stability of neural prosthetic control signals from silicon cortical arrays in rhesus macaque motor cortexJournal of Neural Engineering, 2011
- Decoding the rat forelimb movement direction from epidural and intracortical field potentialsJournal of Neural Engineering, 2011
- Microseizures and the spatiotemporal scales of human partial epilepsyBrain, 2010
- Neuronal loss due to prolonged controlled-current stimulation with chronically implanted microelectrodes in the cat cerebral cortexJournal of Neural Engineering, 2010
- Optimal spacing of surface electrode arrays for brain–machine interface applicationsJournal of Neural Engineering, 2010
- Long term in vitro stability of fully integrated wireless neural interfaces based on Utah slant electrode arrayApplied Physics Letters, 2010
- Spatial characterization of interictal high frequency oscillations in epileptic neocortexBrain, 2009
- Microphysiology of Epileptiform Activity in Human NeocortexJournal Of Clinical Neurophysiology, 2008
- High-frequency oscillations in human temporal lobe: simultaneous microwire and clinical macroelectrode recordingsBrain, 2008