Time Delay of Index Calculation
Open Access
- 1 March 2006
- journal article
- laboratory investigations
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 104 (3) , 488-494
Abstract
Background: On the basis of electroencephalographic analysis, several parameters have been proposed as a measure of the hypnotic component of anesthesia. All currently available indices have different time lags to react to a change in the level of anesthesia. The aim of this study was to determine the latency of three frequently used indices: the Cerebral State Index (Danmeter, Odense, Denmark), the Bispectral Index (Aspect Medical Systems Inc., Newton, MA), and the Narcotrend Index (MonitorTechnik, Bad Bramstedt, Germany). Methods: Artificially generated signals were used to produce up to 14 constant index values per monitor that indicate "awake state," "general anesthesia," and "deep anesthesia" and smaller steps in between. The authors simulated loss of and return to consciousness by changing between the artificial electroencephalographic signals in a full-step and two stepwise approaches and measured the time necessary to adapt the indices to the particular input signal. Results: Time delays between 14 and 155 s were found for all indices. These delays were not constant. Results were different for decreasing and increasing values and between the full-step and the stepwise approaches. Calculation time depended on the particular starting and target index value. Conclusions: The time delays of the tested indices may limit their value in prevention of recall of intraoperative events. Furthermore, different latencies for decreasing and increasing values may indicate a limitation of these monitors for pharmacodynamic studies.Keywords
This publication has 9 references indexed in Scilit:
- The Incidence of Awareness During Anesthesia: A Multicenter United States StudyAnesthesia & Analgesia, 2004
- Narcotrend Index Versus Bispectral Index as Electroencephalogram Measures of Anesthetic Drug Effect During Propofol AnesthesiaAnesthesia & Analgesia, 2004
- Detection of awareness in surgical patients with EEG-based indices—bispectral index and patient state index † ‡British Journal of Anaesthesia, 2003
- The Narcotrend™ - a new EEG monitor designed to measure the depth of anaesthesiaDer Anaesthesist, 2001
- Awareness during anaesthesia: a prospective case studyThe Lancet, 2000
- A Primer for EEG Signal Processing in AnesthesiaAnesthesiology, 1998
- Brief wakeful response to command indicates wakefulness with suppression of memory formation during surgical anesthesiaJournal of Clinical Monitoring and Computing, 1995
- Wakeful response to command indicates memory potential during emergence from general anesthesiaJournal of Clinical Monitoring and Computing, 1995
- ANFIS: adaptive-network-based fuzzy inference systemIEEE Transactions on Systems, Man, and Cybernetics, 1993