Validation of Air as an Equilibration Medium in Gastric Tonometry: An in Vitro Evaluation of Two Techniques for Measuring Air Pco 2
Authors:
Open Access
- 1 February 1998
- journal article
- research article
- Published by SAGE Publications in Anaesthesia and Intensive Care
- Vol. 26 (1) , 46-50
Abstract
This laboratory-based bench study was undertaken to evaluate the accuracy and equilibration characteristics of air and saline respectively as CO 2 equilibrating media in the silicone balloon of a gastric tonometer and to compare two methods of measuring air Pco 2 . Two gastric tonometers were suspended in a bath containing 0.9% saline maintained at 37°C. Certified calibration gases at three different CO 2 concentrations were bubbled into the bath. When the bath Pco 2 measurement was stable the tonometers were primed with 5 ml of air and 2.5 ml normal saline respectively and allowed to equilibrate for 30 and 90 minutes. Following equilibration, samples were aspirated and analysed in duplicate in a blood gas analyser. Bias and precision were calculated from the measured and expected Pco 2 values. A consistent negative bias (21–23%) was seen with air at all three CO 2 concentrations at 30 and 90 minutes with a coefficient of variation between 2.7 and 3.3%. Imprecise data were obtained with saline at different levels of CO 2 . A similar experimental set-up was used to compare air Pco 2 measurement by a blood gas analyser and an infra-red analyser (Tonocap). Similar bias was obtained with the blood gas analyser with respect to air Pco 2 measurement as in experiment 1. The infra-red analyser measurement was highly precise with negligible bias. Air appears to be a better CO 2 equilibration medium during bench testing of tonometry producing a systematic negative offset and requiring a uniform correction factor of 1.25. This correction factor is independent of equilibration time and equilibrating CO 2 concentration. The use of the infra-red analyser eliminates any bias in the measurement of air Pco 2 and obviates the need for a correction factor.Keywords
This publication has 17 references indexed in Scilit:
- In-vivo comparison of gastrointestinal tonometry using the saline technique and a novel automated on-line air device (The Tonocap)Intensive Care Medicine, 1996
- Blood is a more appropriate equilibration fluid for use in gastric tonometry than saline or haemaccelIntensive Care Medicine, 1996
- Combined measurements of blood lactate concentrations and gastric intramucosal pH in patients with severe sepsisCritical Care Medicine, 1995
- Improved P CO 2 measurement in six standard blood gas analysers using a phosphate‐buffered solution for gastric tonometryAnaesthesia, 1995
- Saline Pco2 is an important source of error in the assessment of gastric intramucosal pHCritical Care Medicine, 1994
- Low intramucosal pH is associated with failure to acidify the gastric lumen in response to pentagastrinIntensive Care Medicine, 1994
- Intra-operative gut mucosal hypoperfusion is associated with increased post-operative complications and costIntensive Care Medicine, 1994
- Measuring carbon dioxide tension in saline and alternative solutions: Quantification of bias and precision in two blood gas analyzersCritical Care Medicine, 1994
- Association between gastric intramucosal pH and splanchnic endotoxin, antibody to endotoxin, and tumor necrosis factor-α concentrations in patients undergoing cardiopulmonary bypassCritical Care Medicine, 1993
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986