Dynamic Analysis and Improved LVRT Performance of Multiple DG Units Equipped With Grid-Support Functions Under Unbalanced Faults and Weak Grid Conditions
- 18 December 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 33 (10) , 9017-9032
Abstract
Due to the increased integration of multiple distributed generation (DG) units into the distribution network, riding through short-term faults and supporting the host grid have been requested by the new grid codes in many countries. However, the literature lacks the detailed dynamic analysis and control coordination of multiple grid-connected converter-based DG units, equipped with advanced controllers in the synchronous reference frame. To fill this gap, this paper initially presents a detailed small-signal modeling framework for typical medium-voltage multi-bus power distribution systems with multiple DG units equipped with grid-support functions to operate under the unbalanced conditions. This model encompasses the positive and negative sequences of the current and voltage and is developed for three stages of the fault (i.e., before, during and after the fault) to cover a wide range of system operating points. In addition, to precisely study the interactions among DG units, four different control modes in DG units are considered to study the system dynamics under low-voltage and unbalanced conditions and at different grid strengths. Using the proposed detailed state-space models and based on the small-signal stability analyses, different control parameters are re-designed using the eigenvalue analysis on the complete multi-DG system. As a second contribution, sensitivity analyses are performed to study the effects of different system parameters, such as line characteristics, loading levels, and unbalanced fault characteristics, on the stability of the multi-DG system under unbalanced faults. Comparative simulation and experimental results are also reported to show the accuracy and effectiveness of the theoretical analyses.Keywords
This publication has 28 references indexed in Scilit:
- Assessment and Enhancement of a Full-Scale PMSG-Based Wind Power Generator Performance Under FaultsIEEE Transactions on Energy Conversion, 2016
- Control Strategy to Maximize the Power Capability of PV Three-Phase Inverters During Voltage SagsIEEE Transactions on Power Electronics, 2015
- Scaled Current Tracking Control for Doubly Fed Induction Generator to Ride-Through Serious Grid FaultsIEEE Transactions on Power Electronics, 2015
- A Dual Voltage Control Strategy for Single-Phase PWM Converters With Power Decoupling FunctionIEEE Transactions on Power Electronics, 2014
- Implementation of Fault Ride-Through Techniques of Grid-Connected Inverter for Distributed Energy Resources With Adaptive Low-Pass Notch PLLIEEE Transactions on Power Electronics, 2014
- A Transient Stiffness Measure for Islanding Detection of Multi-DG SystemsIEEE Transactions on Power Delivery, 2014
- Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC ConverterIEEE Transactions on Power Delivery, 2014
- Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability SolutionIEEE Transactions on Power Systems, 2014
- A review of grid code technical requirements for wind farmsIET Renewable Power Generation, 2009
- Distributed Generation as Voltage Support for Single Wire Earth Return SystemsIEEE Transactions on Power Delivery, 2004