Validity of synthetic bone as a substitute for osteoporotic cadaveric femoral heads in mechanical testing
Authors:
Open Access
- 1 April 2012
- journal article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 1 (4) , 50-55
Abstract
Introduction: The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the synthetic material could produce results similar to those of the osteoporotic bone, it could reduce or eliminate the need for testing of implants on bone. Methods: Pushout studies were performed with the dynamic hip screw (DHS) and the DHS Blade in both cadaveric femoral heads and artificial bone substitutes in the form of polyurethane foam blocks of different density. The pushout studies were performed as a means of comparing the force displacement curves produced by each implant within each material. Results: The results demonstrated that test material with a density of 0.16 g/cm3 (block A) produced qualitatively similar force displacement curves for the DHS and qualitatively and quantitatively similar force displacement curves for the DHS Blade, whereas the test material with a density of 0.08 g/cm3 (block B) did not produce results that were predictive of those recorded within the osteoporotic cadaveric femoral heads. Conclusion: This study demonstrates that synthetic material with a density of 0.16 g/cm3 can provide a good substitute for cadaveric osteoporotic femoral heads in the testing of implants. However we do recognise that no synthetic material can be considered as a definitive substitute for bone, therefore studies performed with artificial bone substrates may need to be validated by further testing with a small bone sample in order to produce conclusive results.Keywords
This publication has 22 references indexed in Scilit:
- Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous boneBMC Musculoskeletal Disorders, 2008
- Pullout Strength and Load to Failure Properties of Self-Tapping Cortical Screws in Synthetic and Cadaveric Environments Representative of Healthy and Osteoporotic BoneJournal of Trauma: Injury, Infection & Critical Care, 2008
- Vertically Oriented Femoral Neck Fractures: Mechanical Analysis of Four Fixation TechniquesJournal of Orthopaedic Trauma, 2007
- Experimental evaluation of the holding power/stiffness of the self-tapping bone screws in normal and osteoporotic bone materialClinical Biomechanics, 2006
- Osteoporosis and Skeletal FracturesHSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery, 2006
- Unstable Proximal Extraarticular Tibia FracturesJournal of Orthopaedic Trauma, 2004
- Epidemiology and Mechanism of Injury2000
- Synthetic Materials and Structures Used as Models for Bone1999
- Mechanical validation of whole bone composite femur modelsJournal of Biomechanics, 1996
- Evaluation of experimental and finite element models of synthetic and cadaveric femora for pre-clinical design-analysisClinical Materials, 1994