Abstract
Rapid detection of ultratrace pollutants in complex matrices is a great challenge for studying their environmental behaviors and impacts. In this work, a method is developed by combining covalent organic framework (COF) based solid phase microextraction (SPME) with constant flow desorption ionization mass spectrometry for rapid detection of trace tetrabromobisphenol A (TBBPA) in multiple water media. The limits of detection and qualification are 0.92 and 3.1 ng L-1 for TBBPA, respectively. The linear range is between 0.01 and 10 µg L-1 (R2=0.9992), and the relative standard deviations with single fiber and multiple fibers are 6.4% and 6.7% (0.1 µg L-1, n=9), respectively. The detection of nanogram per liter levels of TBBPA in tap water, river water, sea water and beverage can be achieved in 7 minutes.
Funding Information
  • Shandong Province (2016GSF117039)
  • National Natural Science Foundation of China (21537004, 21874017, 21607161, 21876181)
  • Chinese Academy of Sciences (YZ201642)
  • State Key Laboratory of Environmental Chemistry and Ecotoxicology (KF2015-10)

This publication has 37 references indexed in Scilit: