Cephalomedullary Nail Fixation of Intertrochanteric Femur Fractures: Are Two Proximal Screws Better Than One?
Authors:
- 1 November 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (11) , 577-582
Abstract
Objectives: To analyze radiographic changes in intertrochanteric (IT) fracture alignment after treatment with either a single sliding lag screw or an integrated compressed and locked, dual screw, cephalomedullary nail construct.Design: Retrospective comparative study.Setting: Level 1 regional trauma center.Patients: 1004 OTA/AO 31A, 31B2.1 fractures treated with either a single screw cephalomedullary nail (Gamma 3) or an integrated dual screw cephalomedullary nail (InterTAN) between February 1, 2005, and June 30, 2013. Four hundred thirteen remained after exclusion criteria; 130 were treated with a single screw device (79 stable and 51 unstable), and 283 with an integrated dual screw device (155 stable and 128 unstable).Intervention: Cephalomedullary nail insertion.Outcome Measures: Radiographic analysis included fracture pattern, fracture reduction, neck-shaft angle (NSA), and femoral neck shortening (FNS) differences at 3, 6, and 12 months. Measurements were normalized using known lag screw dimensions, digitally corrected for magnification. Rotation between x-rays was controlled using a ratio of known to measured dimensions. The Mann–WhitneyUtest was used for statistical analysis.Results: The single screw device resulted in 2.5 times more varus collapse (NSA) and 2 times more FNS over 1 year, as compared to the locked, integrated dual screw device, regardless of stability (P< 0.001). NSA and FNS changes were greater for both devices in unstable fracture patterns, but significantly less movement occurred with the dual screw device (P< 0.001).Conclusions: A cephalomedullary nail with 2 integrated proximal screws that can be compressed and then locked seems to maintain initial IT fracture reduction and subsequent position over time, with less varus collapse and less shortening than a single screw device.Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.Keywords
This publication has 18 references indexed in Scilit:
- Malpositioning of the Lag Screws by 1- or 2-screw Nailing Systems for Pertrochanteric Femoral FracturesJournal of Orthopaedic Trauma, 2014
- Biomechanical Evaluation of Interlocking Lag Screw Design in Intramedullary Nailing of Unstable Pertrochanteric FracturesJournal of Orthopaedic Trauma, 2013
- Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fracturesInternational Orthopaedics, 2012
- Femoral Head Lag Screw Position for Cephalomedullary NailsJournal of Orthopaedic Trauma, 2012
- Accuracy of Lag Screw Placement for the Dynamic Hip Screw and the Cephalomedullary NailOrthopedics, 2009
- The Treatment of Intertrochanteric Fractures: Results Using an Intramedullary Nail With Integrated Cephalocervical Screws and Linear CompressionJournal of Orthopaedic Trauma, 2009
- The effect of shortening and varus collapse of the femoral neck on function after fixation of intracapsular fracture of the hipThe Journal of Bone and Joint Surgery. British volume, 2008
- Fracture and Dislocation Classification Compendium - 2007Journal of Orthopaedic Trauma, 2007
- An estimate of the worldwide prevalence, mortality and disability associated with hip fractureOsteoporosis International, 2004
- The Future of Hip Fractures in the United StatesClinical Orthopaedics and Related Research, 1990